Evidence map›Paper›PMID 34154769›Full record

ArticleMedical engineering & physics2021

Virtual implantation technique to estimate endoprosthetic contact of percutaneous osseointegrated devices in the tibia.

Carolyn E Taylor, Heath B Henninger, Kent N Bachus

Open access · greenAbstract read
In one paragraph

Article in Medical engineering & physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Carolyn E TaylorDepartment of Orthopaedics, University of Utah, 590 Wakara Way, Suite A100, Salt Lake City, Utah, United States; Department of Biomedical Engineering, University of Utah, 36 S Wasatch Drive SMBB 3100, Salt Lake City, Utah, United State.
Heath B HenningerDepartment of Orthopaedics, University of Utah, 590 Wakara Way, Suite A100, Salt Lake City, Utah, United States; Department of Biomedical Engineering, University of Utah, 36 S Wasatch Drive SMBB 3100, Salt Lake City, Utah, United State.
Kent N BachusDepartment of Veterans Affairs, 500 Foothill Drive (151), Salt Lake City, UT, United States; Department of Orthopaedics, University of Utah, 590 Wakara Way, Suite A100, Salt Lake City, Utah, United States; Department of Biomedical Engineering, University of Utah, 36 S Wasatch Drive SMBB 3100, Salt Lake City, Utah, United State. Electronic address: kent.bachus@hsc.utah.edu.
University of Utah · US

Funding

Predicting Skeletal Stability of Endoprostheses for Above Elbow AmputeesI01RX000262 · VA · VA SALT LAKE CITY HEALTHCARE SYSTEM · PI BACHUS, KENT N. · 2010 to 2014
–
Percutaneous Osseointegrated Docking System for Above Elbow AmputeesI01RX001246 · VA · VA SALT LAKE CITY HEALTHCARE SYSTEM · PI BACHUS, KENT N. · 2015 to 2018
–
Renewal of Functional Expectations of Transhumeral Percutaneous Osseointegration PatientsI01RX002935 · VA · VA SALT LAKE CITY HEALTHCARE SYSTEM · PI Sujee Jeyapalina · 2019 to 2026
–
RR&D Research Career Scientist Award ApplicationIK6RX003071 · VA · VA SALT LAKE CITY HEALTHCARE SYSTEM · PI BACHUS, KENT N. · 2020 to 2024
–
RRD VA I01 RX000262RRD VA I01 RX001246RRD VA I01 RX002935RRD VA IK6 RX003071
6 · The paper itself

Abstract

Percutaneous osseointegrated (OI) devices have an endoprosthesis attached to the residual bone of an amputated limb, then pass permanently through the skin to be connected to the distal prosthetic componentry outside of the body. Whether the bone-anchoring region of current OI endoprostheses are cylindrical, and/or conical, they require intimate bone-endoprosthesis contact to promote stabilizing bone attachment. However, removing too much cortical bone to achieve more contact leads to thinner and, subsequently, weaker cortical walls. Endoprostheses need to be designed to balance these factors, namely maximizing the contact, while minimizing the volume of bone removed. In this study, 27 human tibias were used to develop and validate a virtual implantation method. Then, 40 additional tibias were virtually implanted with mock cylindrical and conical bone-anchoring regions at seven residual limb lengths to measure resultant bone-endoprosthesis contact and bone removal. The ratio of bone-endoprosthesis contact to bone volume removed showed the conical geometry had more contact area per volume bone removed for all amputation levels (p ≤ 0.001). In both mock devices, cortical penetration of the endoprosthesis at 20% residual length occurred in 74% of cases evaluated, indicating that alternative endoprosthesis geometries may be needed for clinical success in that region of bone.

Indexed as

AmputeesTibiaAmputation, SurgicalCortical BoneHumansOsseointegrationProstheses and ImplantsProsthesis DesignProsthesis ImplantationEndoprosthesis designOsseointegrationVirtual implantation

Identifiers

PMID34154769
PMCPMC8428392
OpenAlexW3164558985

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.