ArticleJournal of applied clinical medical physics2021
Reducing variability among treatment machines using knowledge-based planning for head and neck, pancreatic, and rectal cancer.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 16 citations in OpenAlex.
- Distinguishing model- and environment-related effects in knowledge-based planning of moderately hypofractionated prostate VMAT.Physical and engineering sciences in medicine · 2026Article
- Article
- Systematic comparison of manual, knowledge-based, and feasibility DVH approaches for prostate VMAT: stability and robustness.Physical and engineering sciences in medicine · 2026Article
- Evaluation of deliverable dose-mimicking automated volumetric arc radiation therapy planning for stage III non-small cell lung cancer patients: comparison with a commercial DVH-predicted automated planning system.Journal of radiation research · 2026Article
- Comparative evaluation of two dose-volume histogram prediction tools for treatment planning: Treatment planning quality and dose verification accuracy.Technical innovations & patient support in radiation oncology · 2025Article
- Effect of physical parameter differences on the performance of a knowledge-based partial arc VMAT RapidPlan model for left breast cancer.Frontiers in oncology · 2025Article
- Knowledge-based model building for treatment planning for prostate cancer using commercial treatment planning quality assurance software tools.Radiological physics and technology · 2024Article
- Development and Validation of Single-Optimization Knowledge-Based Volumetric Modulated Arc Therapy Model Plan in Nasopharyngeal Carcinomas.Advances in radiation oncology · 2024Article
- Implementation, Dosimetric Assessment, and Treatment Validation of Knowledge-Based Planning (KBP) Models in VMAT Head and Neck Radiation Oncology.Biomedicines · 2023Article
- Knowledge-based planning for multi-isocenter VMAT total marrow irradiation.Frontiers in oncology · 2022Article
- Using multi-centre data to train and validate a knowledge-based model for planning radiotherapy of the head and neck.Physics and imaging in radiation oncology · 2022Article
- Feasibility of Coplanar VMAT for Brain Metastases Using Halcyon With Knowledge-based Planning from Non-coplanar Plan.In vivo (Athens, Greece)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
Abstract
purposeThis study aimed to assess dosimetric indices of RapidPlan model-based plans for different energies (6, 8, 10, and 15 MV; 6- and 10-MV flattening filter-free), multileaf collimator (MLC) types (Millennium 120, High Definition 120, dual-layer MLC), and disease sites (head and neck, pancreatic, and rectal cancer) and compare these parameters with those of clinical plans.
methodsRapidPlan models in the Eclipse version 15.6 were used with the data of 28, 42, and 20 patients with head and neck, pancreatic, and rectal cancer, respectively. RapidPlan models of head and neck, pancreatic, and rectal cancer were created for TrueBeam STx (High Definition 120) with 6 MV, TrueBeam STx with 10-MV flattening filter-free, and Clinac iX (Millennium 120) with 15 MV, respectively. The models were used to create volumetric-modulated arc therapy plans for a 10-patient test dataset using all energy and MLC types at all disease sites. The Holm test was used to compare multiple dosimetric indices in different treatment machines and energy types.
resultsThe dosimetric indices for planning target volume and organs at risk in RapidPlan model-based plans were comparable to those in the clinical plan. Furthermore, no dose difference was observed among the RapidPlan models. The variability among RapidPlan models was consistent regardless of the treatment machines, MLC types, and energy.
conclusionsDosimetric indices of RapidPlan model-based plans appear to be comparable to the ones based on clinical plans regardless of energies, MLC types, and disease sites. The results suggest that the RapidPlan model can generate treatment plans independent of the type of treatment machine.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.