Evidence map›Paper›PMID 34151502›Full record

ArticleJournal of applied clinical medical physics2021

Evaluation of 4-Hz log files and secondary Monte Carlo dose calculation as patient-specific quality assurance for VMAT prostate plans.

Philipp Szeverinski, Matthias Kowatsch, Thomas Künzler, Marco Meinschad, Patrick Clemens, Alexander F DeVries

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Philipp SzeverinskiInstitute of Medical Physics, Academic Teaching Hospital Feldkirch, Feldkirch, Austria.
Matthias KowatschInstitute of Medical Physics, Academic Teaching Hospital Feldkirch, Feldkirch, Austria.
Thomas KünzlerInstitute of Medical Physics, Academic Teaching Hospital Feldkirch, Feldkirch, Austria.
Marco MeinschadInstitute of Medical Physics, Academic Teaching Hospital Feldkirch, Feldkirch, Austria.
Patrick ClemensDepartment of Radio-Oncology, Academic Teaching Hospital Feldkirch, Feldkirch, Austria.
Alexander F DeVriesDepartment of Radio-Oncology, Academic Teaching Hospital Feldkirch, Feldkirch, Austria.
Landeskrankenhaus Feldkirch · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn this study, 4-Hz log files were evaluated with an independent secondary Monte Carlo dose calculation algorithm to reduce the workload for patient-specific quality assurance (QA) in clinical routine. MATERIALS AND

methodsA total of 30 randomly selected clinical prostate VMAT plans were included. The used treatment planning system (TPS) was Monaco (Elekta, Crawley), and the secondary dose calculation software was SciMoCa (Scientific-RT, Munich). Monaco and SciMoCa work with a Monte Carlo algorithm. A plausibility check of Monaco and SciMoCa was performed using an ionization chamber in the BodyPhantom (BP). First, the original Monaco RT plans were verified with SciMoCa (pretreatment QA). Second, the corresponding 4-Hz log files were converted into RT log file plans and sent to SciMoCa as on-treatment QA. MLC shift errors were introduced for one prostate plan to determine the sensitivity of on-treatment QA. For pretreatment and on-treatment QA, a gamma analysis (2%/1mm/20%) was performed and dosimetric values of PTV and OARs were ascertained in SciMoCa.

resultsPlausibility check of TPS Monaco vs. BP measurement and SciMoCa vs. BP measurement showed valid accuracy for clinical VMAT QA. Using SciMoCa, there was no significant difference in PTV Dmean between RT plan and RT log file plan. Between pretreatment and on-treatment QA, PTV metrics, femur right and left showed no significant dosimetric differences as opposed to OARs rectum and bladder. The overall gamma passing rate (GPR) ranged from 96.10% to 100% in pretreatment QA and from 93.50% to 99.80% in on-treatment QA. MLC shift errors were identified for deviations larger than -0.50 mm and +0.75 mm using overall gamma criterion and PTV Dmean.

conclusionSciMoCa calculations of Monaco RT plans and RT log file plans are in excellent agreement to each other. Therefore, 4-Hz log files and SciMoCa can replace labor-intensive phantom-based measurements as patient-specific QA.

Indexed as

ProstateRadiotherapy, Intensity-ModulatedHumansMaleMonacoQuality Assurance, Health CareRadiotherapy DosageRadiotherapy Planning, Computer-Assistedlog fileMonacoSciMoCaVMAT quality assurance

Identifiers

PMID34151502
PMCPMC8292700
OpenAlexW3173846206

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked