Evidence map›Paper›PMID 34151498›Full record

ArticleJournal of applied clinical medical physics2021

Radiobiological evaluation considering setup error on single-isocenter irradiation in stereotactic radiosurgery.

Hisashi Nakano, Satoshi Tanabe, Ryuta Sasamoto, Takeshi Takizawa, Satoru Utsunomiya, Madoka Sakai, Toshimichi Nakano, Atsushi Ohta, Motoki Kaidu, Hiroyuki Ishikawa

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hisashi NakanoDepartment of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata, Japan.
Satoshi TanabeDepartment of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata, Japan.
Ryuta SasamotoDepartment of Radiological Technology, Niigata University Graduate School of Health Sciences, Niigata, Japan.
Takeshi TakizawaDepartment of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata, Japan.
Satoru UtsunomiyaDepartment of Radiological Technology, Niigata University Graduate School of Health Sciences, Niigata, Japan.
Madoka SakaiDepartment of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata, Japan.
Toshimichi NakanoDepartment of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.
Atsushi OhtaDepartment of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata, Japan.
Motoki KaiduDepartment of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.
Hiroyuki IshikawaDepartment of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.

Funding

MEXT | Japan Society for the Promotion of Science (JSPS) 19K17227
6 · The paper itself

Abstract

purposeWe calculated the dosimetric indices and estimated the tumor control probability (TCP) considering six degree-of-freedom (6DoF) patient setup errors in stereotactic radiosurgery (SRS) using a single-isocenter technique.

methodsWe used simulated spherical gross tumor volumes (GTVs) with diameters of 1.0 cm (GTV 1), 2.0 cm (GTV 2), and 3.0 cm (GTV 3), and the distance (d) between the target center and isocenter was set to 0, 5, and 10 cm. We created the dose distribution by convolving the blur component to uniform dose distribution. The prescription dose was 20 Gy and the dose distribution was adjusted so that D95 (%) of each GTV was covered by 100% of the prescribed dose. The GTV was simultaneously rotated within 0°-1.0° (δR) around the x-, y-, and z-axes and then translated within 0-1.0 mm (δT) in the x-, y-, and z-axis directions. D95, conformity index (CI), and conformation number (CN) were evaluated by varying the distance from the isocenter. The TCP was estimated by translating the calculated dose distribution into a biological response. In addition, we derived the x-y-z coordinates with the smallest TCP reduction rate that minimize the sum of squares of the residuals as the optimal isocenter coordinates using the relationship between 6DoF setup error, distance from isocenter, and GTV size.

resultsD95, CI, and CN were decreased with increasing isocenter distance, decreasing GTV size, and increasing setup error. TCP of GTVs without 6DoF setup error was estimated to be 77.0%. TCP were 25.8% (GTV 1), 35.0% (GTV 2), and 53.0% (GTV 3) with (d, δT

conclusionThe TCP in SRS for multiple brain metastases with a single-isocenter technique may decrease with increasing isocenter distance and decreasing GTV size when the 6DoF setup errors are exceeded (1.0 mm, 1.0°). Additionally, it might be possible to better maintain TCP for GTVs with 6DoF setup errors by using the optimal isocenter position.

Indexed as

Brain NeoplasmsRadiosurgeryHumansRadiobiologyRadiotherapy DosageRadiotherapy Planning, Computer-Assistedbrain metastasessetup errorsingle-isocenter techniquestereotactic radiosurgerytumor control probability

Identifiers

PMID34151498
PMCPMC8292684

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.