Evidence map›Paper›PMID 34150497›Full record

ArticleIntegrative medicine research2021

Ultrasonic device developed for non-invasive moxibustion therapy.

Geonwoo Kim, Young-In Hwang, Yeonhee Ryu, Hak-Joon Kim, Young-Min Bae, Ki-Bok Kim

Open access · goldAbstract read
In one paragraph

Article in Integrative medicine research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 2 countries.

Geonwoo KimEnvironmental Microbial and Food Safety Laboratory, Agricultural Research Service, United States Department of Agriculture, Beltsville, MD, USA.
Young-In HwangCenter for Safety Measurement, Korea Research Institute of Standards and Science, Daejeon, Republic of Korea.
Yeonhee RyuKM Fundamental Research Division, Korea Institute of Oriental Medicine, Daejeon, Republic of Korea.
Hak-Joon KimDepartment of Mechanical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
Young-Min BaeSmart Grid Research Division, Korea Electrotechnology Research Institute, Ansan, Republic of Korea.
Ki-Bok KimCenter for Safety Measurement, Korea Research Institute of Standards and Science, Daejeon, Republic of Korea.
Korea Research Institute of Standards and Science · KRAgricultural Research Service · USKorea Electrotechnology Research Institute · KRKorea Institute of Oriental Medicine · KRSungkyunkwan University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecently, some adverse effects of moxibustion has been reported such as burns, smoke, allergies, and so on. To overcome the adverse effects of traditional moxibustion, an ultrasonic moxibustion device (UMD) was designed, simulated, fabricated, and tested. The objective of this study is to provide detailed information about the main design parameters, simulation outcome, and performance-test results.

methodsThe main components of the UMD are a 1-MHz ultrasonic transducer (UT) with concave lens, and its applicator. The acoustic pressure and temperature distribution of the UT was simulated and described graphically using COMSOL software, which is based on the finite element method (FEM). Experimental verification of the temperature distribution was performed on the skin of pork. The temperature-change profiles of pork in relation to increase of therapy time were obtained at an unfocused point (2 mm) and at a focal distance of 13 mm. For the performance test, moxibustion therapy was conducted on the abdominal skin of mice for 120 min using the new UMD and its histological images were acquired to analyze the skin-tissue damage.

resultsThe FEM simulation of temperature distribution and acoustic pressure agreed with the experimental outcome. Histological images showed that there was no skin-tissue damage to the mouse abdomens after therapy. The results clearly show that the newly developed UMD can overcome the disadvantages of traditional moxibustion therapy and achieve the proposed design parameters.

conclusionThe FEM simulation and performance tests provided valuable information about developing future UMDs. In addition, its performance can be compared with traditional moxibustion therapy for future study.

Indexed as

AcupointFEM simulationMoxibustionUltrasonic transducer

Identifiers

PMID34150497
PMCPMC8190483
OpenAlexW3163126879

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.