Evidence map›Paper›PMID 34150203›Full record

ArticleAnnals of medicine and surgery (2012)2021

Patient-specific implants for craniomaxillofacial surgery: A manufacturer's experience.

Ganesha K Thayaparan, Philip M Lewis, Robert G Thompson, Paul S D'Urso

Abstract readCase Reports
In one paragraph

Article in Annals of medicine and surgery (2012), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Mapping Biomaterial Complexity by Machine Learning.Tissue engineering. Part A · 2024
    Review
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ganesha K ThayaparanNeuroscience Institute, Epworth Healthcare, Richmond, Victoria, Australia.
Philip M LewisDepartment of Surgery, Central Clinical School, Faculty of Medicine, Nursing & Health Sciences, Monash University, Melbourne, Victoria, Australia.
Robert G ThompsonAnatomics Pty Ltd, East Bentleigh, Victoria, Australia.
Paul S D'UrsoNeuroscience Institute, Epworth Healthcare, Richmond, Victoria, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Additive manufacturing technologies have enabled the development of customised implants for craniomaxillofacial applications using biomaterials such as polymethylmethacrylate (PMMA), porous high-density polyethylene (pHDPE), and titanium mesh. This study aims to report an Australian manufacturer's experience in developing, designing and supplying patient-specific craniomaxillofacial implants over 23 years and summarise feedback received from clinicians. The authors conducted a retrospective review of the manufacturer's implant database of orders placed for custom craniomaxillofacial implants between 1996 and 2019. The variables collected included material, country of order, gender, patient age, and reported complications, which included a measure of custom implant "fit" and adverse events. The development of critical checkpoints in the custom manufacturing process that minimise clinical or logistical non-conformities is highlighted and discussed. A total of 4120 patient-specific implants were supplied, of which 2689 were manufactured from PMMA, 885 from titanium mesh, and 546 from pHDPE. The majority of the implants were used in Australia (2260), United Kingdom (412), Germany (377), and New Zealand (338). PMMA was the preferred material for cranial implants whereas pHDPE was preferred for maxillofacial applications. Age or gender did not influence the material choice. Implant "fit" and adverse outcomes were used as a metric of implant performance. Between 2007 and 2019 there were 37 infections (0.98%) and 164 non-conformities recorded of which 75 (1.8%) were related to implant 'fit'. Our experience demonstrates a safe, reliable, and clinically streamlined manufacturing process which supports surgeons that require bespoke craniomaxillofacial solutions for reconstruction surgery.

Indexed as

Additive manufacturingPatient-specificPolymethylmethacrylatePorous high-density polyethyleneTitanium mesh

Identifiers

PMID34150203
PMCPMC8193107

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.