ArticleFrontiers in physiology2021
Identification of Transient Noise to Reduce False Detections in Screening for Atrial Fibrillation.
Article in Frontiers in physiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- From wrist to heart: clinical validation and real-world translation of wearable and portable AI-enhanced electrocardiography.European heart journal. Digital health · 2026Review
- Detection of Non-Sustained Supraventricular Tachycardia in Atrial Fibrillation Screening.IEEE journal of translational engineering in health and medicine · 2024Article
- Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Screening for atrial fibrillation (AF) with a handheld device for recording the ECG is becoming increasingly popular. The poorer signal quality of such ECGs may lead to false detection of AF, often caused by transient noise. Consequently, the need for expert review in AF screening can become extensive. A convolutional neural network (CNN) is proposed for transient noise identification in AF detection. The network is trained using the events produced by a QRS detector, classified into either true beat detections or false detections. The CNN and a low-complexity AF detector are trained and tested using the StrokeStop I database, containing 30-s ECGs from mass screening for AF in the elderly population. Performance evaluation of the CNN-based quality control using a subset of the database resulted in sensitivity, specificity, and accuracy of 96.4, 96.9, and 96.9%, respectively. By inserting the CNN before the AF detector, the false AF detections were reduced by 22.5% without any loss in sensitivity. The results show that the number of recordings calling for expert review can be significantly reduced thanks to the identification of transient noise. The reduction of false AF detections is directly linked to the time and cost spent on expert review.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.