Pressure monitoring devices may undetect epidural space: a report on the use of Compuflo® system for epidural injection.
Article in Journal of clinical monitoring and computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 10 citations in OpenAlex.
- To the editor: comments on the paper: pressure monitoring devices may undetect epidural space: a report on the use of Compuflo® system for epidural injection.Journal of clinical monitoring and computing · 2022Article
- Reply to Capogna et al.Journal of clinical monitoring and computing · 2022Article
- Epidural Steroid Injections for Low Back Pain: A Narrative Review.International journal of environmental research and public health · 2021Review
Corrections and comments
- Commented on by
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Lumbar epidural infiltration (EI) is a feasible procedure performed in pain therapy. Even though epidural analgesia is widely applied, it remains a blind technique, based on the operator's hand sensations, and it is associated with significant failure rate and several potential complications. Compuflo® (Compuflo, Milestone Scientific, Livingston, NJ) is a computerized injection pump which precisely detects the real time pressure at the tip of a Tuohy needle when placed in human tissues, thanks to a continuous fluid path. In our institution, we usually perform EI for chronic back pain guided by the Compuflo device, especially for expected difficult procedures. However, we report 6 false negative cases on a total number of 60 procedures in which the Compuflo system didn't meet the criteria of epidural space entry, even though the epidural space was actually reached. A mild pressure decrease (less than 50%) which lasted for more than 5 s was reported on the monitor, and the acoustic signal changed in a little bit lower sound, without a clear indication on stopping or not the needle advancement. This unspecific drop in monitored pressure gives false negatives using the Compuflo® system and may lead to excessive advancing of the needle. In conclusion, we consider the epidural pressure monitoring device Compuflo as a tool which may be able to ease the correct positioning of an epidural needle. The percentage of 10% false negative identifications of the epidural space in our case series however suggests more investigations on adequate or specific settings for this epidural system. In the meantime, in chronic pain patients, this anesthetic technique should only be used by experienced hands.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.