ReviewJournal of medical radiation sciences2021
Imaging modalities for endoleak surveillance.
Review in Journal of medical radiation sciences, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 19 citations in OpenAlex.
- The Applications of Spectral CT in Interventional Radiology: Innovations in Diagnosis and Intra-procedural Guidance.Cardiovascular and interventional radiology · 2026Review
- Article
- Outcomes associated with type II endoleaks after infrarenal endovascular aneurysm repair in the Vascular Quality Initiative linked to Medicare claims.Journal of vascular surgery · 2025Article
- A Pictorial Review of Current Approaches in Endoleak Imaging.Interventional radiology (Higashimatsuyama-shi (Japan) · 2025Review
- Golden-angle radial sparse parallel (GRASP) magnetic resonance angiography (MRA) for endoleak evaluation after endovascular repair of the aorta: a prospective comparison to conventional time-resolved MRA.Quantitative imaging in medicine and surgery · 2024Article
- Dynamic Radial MR Imaging for Endoleak Surveillance after Endovascular Repair of Abdominal Aortic Aneurysms with Inconclusive CT Angiography: A Prospective Study.Journal of clinical medicine · 2024Article
- CIRSE Standards of Practice on Management of Endoleaks Following Endovascular Aneurysm Repair.Cardiovascular and interventional radiology · 2024Article
- [Endovascular aortic repair of endoleaks : Diagnosis, treatment, and outcomes].Radiologie (Heidelberg, Germany) · 2022Review
- [Isolated iliac artery aneurysm : Clinical background and interventional treatment strategies].Radiologie (Heidelberg, Germany) · 2022Review
- EVAR Follow-Up with Ultrasound Superb Microvascular Imaging (SMI) Compared to CEUS and CT Angiography for Detection of Type II Endoleak.Diagnostics (Basel, Switzerland) · 2022Article
- Imaging modalities for endoleak surveillance.Journal of medical radiation sciences · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
As the global population ages, the issue of abdominal aortic aneurysm continues to grow. With the evolution of new devices and refined operative technique, aneurysm treatment via endovascular aortic repair is becoming increasingly favourable. This, however, is not without drawbacks, where regular surveillance is paramount to long-term success and detection of post-procedure complications. Of these complications, endoleak is the most notable and poses the greatest risk of potential future aortic rupture. The purpose of this review paper is to discuss the armada of imaging modalities used in the detection and evaluation of endoleak and their varying usefulness. Plain abdominal X-ray is a cost-effective tool in detecting gross graft abnormalities such as stent migration or deformity (kinking or fracture). Though it may raise suspicion for endoleak, X-ray does not allow accurate classification of endoleak type when used alone. Duplex ultrasonography quantifies both aortic anatomy and real time flow dynamics. Most screening programmes are conducted using two-dimensional ultrasound. Unfortunately, observer and equipment variability may lead to surveillance discrepancies-but reduced when utilising a dedicated vascular sonography laboratory. Contrast enhanced ultrasonography is a promising alternative to computed tomography, though still is emerging. Computed tomography angiography certainly has disadvantages (ionising radiation, contrast-nephropathy, limited differentiation of endoleak type)-however, it provides near-real surgical dimensions and highlights graft complications and concomitant disease (such as neighbouring infection). With widespread availability and short scan time, it certainly remains valuable in surveillance. Magnetic resonance angiography has a similar sensitivity to computed tomography (minus the radiation), however is plagued by movement and metal artefact. Other novel modalities in endoleak surveillance include four-dimensional ultrasound, multiplanar intra-operative probes, nuclear medicine and wall stress analysis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.