Evidence map›Paper›PMID 34145641›Full record

ArticleAdvanced materials (Deerfield Beach, Fla.)2021

Multimodal Digital X-ray Scanners with Synchronous Mapping of Tactile Pressure Distributions using Perovskites.

Jiuk Jang, Sangyoon Ji, G Krishnamurthy Grandhi, Han Bin Cho, Won Bin Im, Jang-Ung Park

Abstract read
In one paragraph

Article in Advanced materials (Deerfield Beach, Fla.), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jiuk JangNano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea.ORCID https://orcid.org/0000-0002-1222-7929
Sangyoon JiNano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea.
G Krishnamurthy GrandhiDivision of Materials Science and Engineering, Hanyang University, Seoul, 04763, Republic of Korea.
Han Bin ChoDivision of Materials Science and Engineering, Hanyang University, Seoul, 04763, Republic of Korea.
Won Bin ImDivision of Materials Science and Engineering, Hanyang University, Seoul, 04763, Republic of Korea.
Jang-Ung ParkNano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea.ORCID https://orcid.org/0000-0003-1522-4958

Funding

Bio & Medical Technology Development Program 2018M3A9F1021649Ministry of Science & ICT (MSIT) of KoreaMinistry of Trade, Industry and EnergyNano Material Technology Development Program 2016M3A7B4910635National Research Foundation 2016R1A5A1009926National Research Foundation 2017R1A2B3011967National Research Foundation 2019R1A2B5B03069358Technology Innovation Program 20010366Technology Innovation Program (Center for Super Critical Material Industrial Technology) 20013621Yonsei University 2019-22-0228
6 · The paper itself

Abstract

Visual and tactile information are the key intuitive perceptions in sensory systems, and the synchronized detection of these two sensory modalities can enhance accuracy of object recognition by providing complementary information between them. Herein, multimodal integration of flexible, high-resolution X-ray detectors with a synchronous mapping of tactile pressure distributions for visualizing internal structures and morphologies of an object simultaneously is reported. As a visual-inspection method, perovskite materials that convert X-rays into charge carriers directly are synthesized. By incorporating pressure-sensitive air-dielectric transistors in the perovskite components, X-ray detectors with dual modalities (i.e., vision and touch) are attained as an active-matrix platform for digital visuotactile examinations. Also, in vivo X-ray imaging and pressure sensing are demonstrated using a live rat. This multiplexed platform has high spatial resolution and good flexibility, thereby providing highly accurate inspection and diagnoses even for the distorted images of nonplanar objects.

Indexed as

lead halide perovskitesmultimodal sensorsperovskitespressure sensorstactile sensorsX-ray detectors

Identifiers

PMID34145641
PMCPMC11468999

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.