Evidence map›Paper›PMID 34145556›Full record

ArticleCardiovascular engineering and technology2022

Personalized Pre- and Post-Operative Hemodynamic Assessment of Aortic Coarctation from 3D Rotational Angiography.

Cosmin-Ioan Nita, Andrei Puiu, Daniel Bunescu, Lucian Mihai Itu, Viorel Mihalef, Gouthami Chintalapani, Aimee Armstrong, Jeffrey Zampi, Lee Benson, Puneet Sharma and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular engineering and technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Cosmin-Ioan NitaAdvanta, Siemens SRL, 3A Eroilor, 500007, Brasov, Romania.
Andrei PuiuAdvanta, Siemens SRL, 3A Eroilor, 500007, Brasov, Romania.
Daniel BunescuAdvanta, Siemens SRL, 3A Eroilor, 500007, Brasov, Romania.
Lucian Mihai ItuAdvanta, Siemens SRL, 3A Eroilor, 500007, Brasov, Romania. lucian.itu@siemens.com.
Viorel MihalefDigital Services, Digital Technology & Innovation, Siemens Healthineers, 755 College Road, Princeton, NJ, 08540, USA.
Gouthami ChintalapaniAdvanced Therapies, Siemens Healthineers, Malvern, USA.
Aimee ArmstrongThe Heart Center, Nationwide Children's Hospital, Columbus, OH, USA.
Jeffrey ZampiThe Division of Pediatric Cardiology, University of Michigan, Ann Arbor, MI, USA.
Lee BensonThe Division of Cardiology, The Labatt Family Heart Center, The Hospital for Sick Children, Toronto, Canada.
Puneet SharmaDigital Services, Digital Technology & Innovation, Siemens Healthineers, 755 College Road, Princeton, NJ, 08540, USA.
Saikiran RapakaDigital Services, Digital Technology & Innovation, Siemens Healthineers, 755 College Road, Princeton, NJ, 08540, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCoarctation of Aorta (CoA) is a congenital disease consisting of a narrowing that obstructs the systemic blood flow. This proof-of-concept study aimed to develop a framework for automatically and robustly personalizing aortic hemodynamic computations for the assessment of pre- and post-intervention CoA patients from 3D rotational angiography (3DRA) data.

methodsWe propose a framework that combines hemodynamic modelling and machine learning (ML) based techniques, and rely on 3DRA data for non-invasive pressure computation in CoA patients. The key features of our framework are a parameter estimation method for calibrating inlet and outlet boundary conditions, and regional mechanical wall properties, to ensure that the computational results match the patient-specific measurements, and an improved ML based pressure drop model capable of predicting the instantaneous pressure drop for a wide range of flow conditions and anatomical CoA variations.

resultsWe evaluated the framework by investigating 6 patient datasets, under pre- and post-operative setting, and, since all calibration procedures converged successfully, the proposed approach is deemed robust. We compared the peak-to-peak and the cycle-averaged pressure drop computed using the reduced-order hemodynamic model with the catheter based measurements, before and after virtual and actual stenting. The mean absolute error for the peak-to-peak pressure drop, which is the most relevant measure for clinical decision making, was 2.98 mmHg for the pre- and 2.11 mmHg for the post-operative setting. Moreover, the proposed method is computationally efficient: the average execution time was of only [Formula: see text] minutes on a standard hardware configuration.

conclusionThe use of 3DRA for hemodynamic modelling could allow for a complete hemodynamic assessment, as well as virtual interventions or surgeries and predictive modeling. However, before such an approach can be used routinely, significant advancements are required for automating the workflow.