ArticleThe British journal of radiology2021
Improving reference standards for validation of AI-based radiography.
Article in The British journal of radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Evaluating the Test Characteristics of a Prototype for AI-Assisted Radiographic Detection.Dentistry journal · 2026Article
- Buccal or palatal? AI-based localization of impacted maxillary canines using panoramic radiographs.BMC medical imaging · 2026Article
- Evaluation of the diagnostic reliability of an AI prototype in detecting clinical features from dental photographs-original research.Frontiers in dental medicine · 2026Article
- Clinical scale of artificial intelligence-based nerve segmentation on ultrasound: a pilot validation study.Frontiers in medicine · 2026Article
- Data annotation and its evaluation in artificial intelligence-based anatomy recognition for ultrasound-guided regional anesthesia: a clinical perspective.Frontiers in medicine · 2026Article
- Artificial intelligence-based quantification of lymphocytes in feline small intestinal biopsies.Veterinary pathology · 2025Article
- Ethical framework for responsible foundational models in medical imaging.Frontiers in medicine · 2025Review
- Artificial Intelligence in the Non-Invasive Detection of Melanoma.Life (Basel, Switzerland) · 2024Review
- Assessing the Performance of Artificial Intelligence Models: Insights from the American Society of Functional Neuroradiology Artificial Intelligence Competition.AJNR. American journal of neuroradiology · 2024Article
- Performance changes due to differences among annotating radiologists for training data in computerized lesion detection.International journal of computer assisted radiology and surgery · 2024Article
- Multicentre external validation of a commercial artificial intelligence software to analyse chest radiographs in health screening environments with low disease prevalence.European radiology · 2023Article
- Critical Appraisal of Artificial Intelligence-Enabled Imaging Tools Using the Levels of Evidence System.AJNR. American journal of neuroradiology · 2023Article
- Hurdles to Artificial Intelligence Deployment: Noise in Schemas and "Gold" Labels.Radiology. Artificial intelligence · 2023Article
- Repeatability of radiographic assessments for feline hip dysplasia suggest consensus scores in radiology are more uncertain than commonly assumed.Scientific reports · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveDemonstrate the importance of combining multiple readers' opinions, in a context-aware manner, when establishing the reference standard for validation of artificial intelligence (AI) applications for,
methods1100 frontal chest radiographs were evaluated for 6 findings: airspace opacity, cardiomegaly, pulmonary edema, fracture, nodules, and pneumothorax. Each image was reviewed by six radiologists, first individually and then via asynchronous adjudication (web-based discussion) in two panels of three readers to resolve disagreements within each panel. We quantified the reproducibility of each method by measuring interreader agreement.
resultsPanel-based majority vote improved agreement relative to individual readers for all findings. Most disagreements were resolved with two rounds of adjudication, which further improved reproducibility for some findings, particularly reducing misses. Improvements varied across finding categories, with adjudication improving agreement for cardiomegaly, fractures, and pneumothorax.
conclusionThe likelihood of interreader agreement, even within panels of US board-certified radiologists, must be considered before reads can be used as a reference standard for validation of proposed AI tools. Agreement and, by extension, reproducibility can be improved by applying majority vote, maximum sensitivity, or asynchronous adjudication for different findings, which supports the development of higher quality clinical research. ADVANCES IN KNOWLEDGE: A panel of three experts is a common technique for establishing reference standards when ground truth is not available for use in AI validation. The manner in which differing opinions are resolved is shown to be important, and has not been previously explored.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.