Evidence map›Paper›PMID 34142493›Full record

ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2021

[Digital study of the ideal position of lag screw internal fixation in the anterior column of the acetabulum].

Yazhi Bai, Qiang Liu

Abstract read
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. [Single Kocher-Langenbeck approach combined with anterograde channel screw technique in treatment of acetabular transverse and posterior wall fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yazhi BaiShanxi Medical University, Taiyuan Shanxi, 030032, P.R.China.
Qiang LiuDepartment of Orthopedics, Shanxi Bethune Hospital, Taiyuan Shanxi, 030032, P.R.China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo find the ideal position of lag screw internal fixation in the anterior column of acetabulum by digital technology, and measure its related parameters, so as to improve the accuracy of lag screw implantation.

methodsThe CT scan data of 266 semi-pelvic raw in 133 cases (78 males and 55 females, aged 18-65 years old with an average age of 42 years) were collected between January 2019 and January 2020 to compose three-dimensional models. According to the relationship between the peripheral bone cortex of the anatomical channel and the lag screw, a new standard for the ideal position of lag screw fixation in the anterior column of acetabulum was proposed to simulate the implantation of the screw. After the screw was in the ideal position, the following indicators were measured: the maximum allowable diameter of the virtual screw (the diameter of the cylinder up to the new standard, R), the length (the distance between the center of the nail point on both sides, L); the position of the retrograde nail point (the interval between the nail insertion points and the midpoint of the pubic symphysis and the pubic tubercle, respectively, D1 and D2) and the position of the antegrade nail insertion point (the distance between the nail insertion point and the anterior superior iliac spine, the major ischial notch, and the vertical distance between the nail insertion point and the apex of the posterior upper edge of the acetabulum, respectively, D3, D4, D5); and the direction of the virtual screw at the ideal position (the angle between the screw and the horizontal plane, sagittal plane, and coronal plane, respectively, ∠β, ∠γ, ∠δ) were calculated.

resultsThe maximum allowable diameter of virtual screws was 5.70-14.10 mm for males, with an average of 9.25 mm; for females, it was 4.40-10.40 mm with an average of 7.29 mm. The antegrade insertion point of the anteroposterior acetabular lag screw was located at 2.0-2.5 cm above the apex of the acetabulum, which was almost the same distance from the anterior superior iliac spine and the ischial notch, about 5 cm; the insertion point of the retrograde implant was located at the pubic bone 2.5-3.0 cm below the nodule. When the acetabular anterior column screw was in the ideal position, there was no significant difference in the comparison of ∠β and ∠γ between the male and the female (

conclusionIn the bony channel of the anterior column of the acetabulum, all males can accommodate screws with a diameter of <5.70 mm, and females can accommodate screws with a diameter of <4.40 mm. The anterograde or retrograde screw insertion points are different for male and female. The use of digital technology to individually measure the appropriate screw parameters can improve the accuracy and stability of the lag screw internal fixation for acetabular anterior column fractures.

Indexed as

Fractures, BonePubic SymphysisAcetabulumAdolescentAdultAgedBone ScrewsFemaleFracture Fixation, InternalHumansMaleMiddle AgedTomography, X-Ray ComputedYoung AdultAnterior acetabular columnbony channeldigitizationideal locationlag screw

Identifiers

PMID34142493
PMCPMC8218193

What OpenQuestion holds

Textmetadata
Read underepoch 390