ArticleTranslational vision science & technology2021
Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach.
Article in Translational vision science & technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 15 citations in OpenAlex.
- Assessment of the Orbit® subretinal delivery system (Orbit® SDS device) and prototypes in adult and juvenile canine eyes.Drug delivery and translational research · 2026Article
- Optimized Minimally Invasive Transscleral Subretinal Injection Technique in Mouse.Journal of visualized experiments : JoVE · 2025Article
- OCT in Oncology and Precision Medicine: From Nanoparticles to Advanced Technologies and AI.Bioengineering (Basel, Switzerland) · 2025Review
- Optical coherence tomography for noninvasive monitoring of drug delivery.Advanced drug delivery reviews · 2025Review
- SpecstatOR: speckle statistics-based iOCT segmentation network for ophthalmic surgery.Biomedical optics express · 2025Article
- Gene therapy for choroideremia: progress, potential and pitfalls.Expert opinion on biological therapy · 2025Review
- New Directions for Ophthalmic OCT - Handhelds, Surgery, and Robotics.Translational vision science & technology · 2025Review
- Advances in technical methods and applications of subretinal injections in experimental animals.Frontiers in veterinary science · 2025Review
- Seasonal Variation in ATP-Induced Retinal Damage in the Cone-Dominant 13-Lined Ground Squirrel.Translational vision science & technology · 2024Article
- Bruch's Membrane: A Key Consideration with Complement-Based Therapies for Age-Related Macular Degeneration.Journal of clinical medicine · 2023Review
- Subretinal Injection Techniques for Retinal Disease: A Review.Journal of clinical medicine · 2022Review
- Intraoperative OCT-Guided Volumetric Measurements of Subretinal Therapy Delivery in Humans.Journal of vitreoretinal diseasesArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
Abstract
Purpose: To investigate the use of imaging modalities in the volumetric measurement of the subretinal space and examine the volume of subretinal blebs created by a subretinal drug delivery device utilizing microscope-integrated optical coherence tomography (MIOCT). Methods: An MIOCT image-based volume measurement method was developed and assessed for accuracy and reproducibility by imaging ceramic spheres of known size that were surgically implanted into ex vivo porcine eyes. This method was then used to measure subretinal blebs created in 10 porcine eyes by injection of balanced salt solution utilizing a subretinal delivery device via a suprachoroidal cannula. Bleb volumes obtained from MIOCT were compared to the intended injection volume. Results: Validation of image-based volume measurements of ceramic spheres showed accuracy to ±0.029 µL (5.6%) for objects imaged over the posterior pole and ±0.025 µL (4.8%) over peripheral retina. The mean expected injection volume from extraocular tests of the suprachoroidal cannula was 66.44 µL (σ = 2.4 µL). The mean injection volume as measured by the MIOCT imaging method was 54.8 µL (σ = 12.3 µL), or 82.48% of expected injection volume. Conclusions: MIOCT can measure the volume of subretinal blebs with accuracy and precision. The novel suprachoroidal approach using a subretinal delivery device was able to deliver greater than 80% of expected injection volume into the subretinal space, as assessed by MIOCT. Translational Relevance: MIOCT provides a method for visualization, and analysis of images enables surgeons to quantify and evaluate the success of subretinal drug delivery via a suprachoroidal approach.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.