Evidence map›Paper›PMID 34137836›Full record

ArticleTranslational vision science & technology2021

Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach.

Ananth Sastry, Jianwei D Li, William Raynor, Christian Viehland, Zhenxi Song, Liangyu Xu, Sina Farsiu, Joseph A Izatt, Cynthia A Toth, Lejla Vajzovic

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Gene therapy for choroideremia: progress, potential and pitfalls.Expert opinion on biological therapy · 2025
    Review
  7. New Directions for Ophthalmic OCT - Handhelds, Surgery, and Robotics.Translational vision science & technology · 2025
    Review
  8. Review
  9. Article
  10. Review
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Ananth SastryDepartment of Ophthalmology, Duke University of School of Medicine, Durham, NC, USA.
Jianwei D LiDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
William RaynorDepartment of Ophthalmology, Duke University of School of Medicine, Durham, NC, USA.
Christian ViehlandDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
Zhenxi SongDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
Liangyu XuDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
Sina FarsiuDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
Joseph A IzattDepartment of Biomedical Engineering, Duke University, Durham, NC, USA.
Cynthia A TothDepartment of Ophthalmology, Duke University of School of Medicine, Durham, NC, USA.
Lejla VajzovicDepartment of Ophthalmology, Duke University of School of Medicine, Durham, NC, USA.
Duke University · US

Funding

Intraoperative OCT Guidance of Intraocular SurgeryR01EY023039 · NEI · DUKE UNIVERSITY · PI IZATT, JOSEPH A, TOTH, CYNTHIA ANN · 2013 to 2016
$3.9M
Intraoperative OCT Guidance of Intraocular SurgeryU01EY028079 · NEI · DUKE UNIVERSITY · PI KUO, ANTHONY NANLIN, TOTH, CYNTHIA ANN · 2018 to 2022
$3.8M
NEI NIH HHS R01 EY023039NEI NIH HHS U01 EY028079
6 · The paper itself

Abstract

Purpose: To investigate the use of imaging modalities in the volumetric measurement of the subretinal space and examine the volume of subretinal blebs created by a subretinal drug delivery device utilizing microscope-integrated optical coherence tomography (MIOCT). Methods: An MIOCT image-based volume measurement method was developed and assessed for accuracy and reproducibility by imaging ceramic spheres of known size that were surgically implanted into ex vivo porcine eyes. This method was then used to measure subretinal blebs created in 10 porcine eyes by injection of balanced salt solution utilizing a subretinal delivery device via a suprachoroidal cannula. Bleb volumes obtained from MIOCT were compared to the intended injection volume. Results: Validation of image-based volume measurements of ceramic spheres showed accuracy to ±0.029 µL (5.6%) for objects imaged over the posterior pole and ±0.025 µL (4.8%) over peripheral retina. The mean expected injection volume from extraocular tests of the suprachoroidal cannula was 66.44 µL (σ = 2.4 µL). The mean injection volume as measured by the MIOCT imaging method was 54.8 µL (σ = 12.3 µL), or 82.48% of expected injection volume. Conclusions: MIOCT can measure the volume of subretinal blebs with accuracy and precision. The novel suprachoroidal approach using a subretinal delivery device was able to deliver greater than 80% of expected injection volume into the subretinal space, as assessed by MIOCT. Translational Relevance: MIOCT provides a method for visualization, and analysis of images enables surgeons to quantify and evaluate the success of subretinal drug delivery via a suprachoroidal approach.

Indexed as

Tomography, Optical CoherenceAnimalsReproducibility of ResultsRetinaSwine

Identifiers

PMID34137836
PMCPMC8212437
OpenAlexW3168421309

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.