Evidence map›Paper›PMID 34136611›Full record

ArticleArthroplasty today2021

Total Hip Arthroplasty Using a Hemispherical Uncemented Dual-Mobility Cup Results in Satisfactory Clinical Outcomes and No Dislocations at 2 years.

Loic Schneider, Frédéric Châtain, Gilles Estour, Sonia Ramos-Pascual, Luca Nover, Nicolas Bonin

Open access · goldAbstract read
In one paragraph

Article in Arthroplasty today, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Loic SchneiderClinique Mutualiste MFL SSAM, Saint-Etienne, France.
Frédéric ChâtainPole Santé Axone, Saint-Martin-d'Hères, France.
Gilles EstourMedipole de Savoie, Challe-les-Eaux, France.
Sonia Ramos-PascualReSurg SA, Nyon, Switzerland.
Luca NoverReSurg SA, Nyon, Switzerland.
Nicolas BoninRamsay Santé, Clinique de la Sauvegarde, Lyon-Ortho-Clinic, France.
Federal Roads Office · CHClinique Mutualiste Chirurgicale · FRGénérale de Santé · FRMédipole Garonne · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe authors performed total hip arthroplasty (THA) using a novel hemispherical dual-mobility (DM) acetabular cup without a protrusive cylindro-spherical rim, intended to reduce risks of iliopsoas impingement without requiring changes to conventional intraoperative positioning as with unipolar cups. We aim to determine clinical scores and rates of dislocations, complications, and revisions of this hemispherical DM cup, with the hypothesis that this novel design would result in clinical scores and dislocation rates comparable to other contemporary DM cups with protrusive cylindro-spherical rims.

methodsWe assessed 332 consecutive uncemented THAs performed using a hemispherical DM cup, at a minimum 2-year follow-up, using modified Harris Hip Score (mHHS) and Oxford Hip Score (OHS), and noting complications and revisions. Regression analyses were conducted to determine if mHHS and OHS depended on any independent factors.

resultsAt 2.8 ± 0.5 years (range, 2-5), 2 patients (0.6%) had stem and cup revisions, 3 patients (1%) had isolated stem revisions, 13 patients (4%) died, and none were lost to follow-up. No dislocations occurred. For the final cohort of 305 patients (314 hips) with their original implants in place, mHHS was 92 ± 12 (range, 46-100), and OHS was 57 ± 5 (range, 34-60). Multivariable analyses revealed that mHHS and OHS decreased significantly with age (β = -0.35,

conclusionsWith no dislocations and satisfactory clinical scores, this sizable cohort confirms that the novel hemispherical DM cup studied is effective at preventing dislocations, although longer-term follow-up remains necessary to ascertain the longevity of clinical outcomes and radiographic stability. LEVEL OF EVIDENCE: Level IV, multicentric retrospective case series.

Indexed as

Clinical outcomeDislocationsDual-mobility cupRevisionSurvivalUncemented THA

Identifiers

PMID34136611
PMCPMC8181579
OpenAlexW3171419466

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.