Evidence map›Paper›PMID 34136609›Full record

ArticleArthroplasty today2021

A Single-Center Randomized Prospective Study Investigating the Efficacy of Various Wound Closure Devices in Reducing Postoperative Wound Complications.

Simon Greenbaum, Stephen Zak, Paul J Tesoriero, Hayeem Rudy, Jonathan Vigdorchik, William J Long, Ran Schwarzkopf

Open access · goldAbstract read
In one paragraph

Article in Arthroplasty today, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Dermatitis after spine fusion caused by liquid adhesive (2-Octyl cyanoacrylate).Journal of the Pediatric Orthopaedic Society of North America · 2024
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Simon GreenbaumDepartment of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, NY.
Stephen ZakDepartment of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, NY.
Paul J TesorieroDepartment of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, NY.
Hayeem RudyDepartment of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, NY.
Jonathan VigdorchikAdult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY.
William J LongDepartment of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, NY.
Ran SchwarzkopfDepartment of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, NY.
New York University Langone Orthopedic Hospital · USHospital for Special Surgery · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSutures and staples are the mainstay wound closure techniques in total joint arthroplasty. Newer techniques such as zipper devices and novel skin adhesives have emerged because of their potential to decrease operative time and possibly minimize complications. The aim of this study is to compare these newer techniques against conventional sutures with respect to wound complications, closure time, and costs.

methodsA single-center randomized control trial was conducted on 160 patients (52 zipper, 55 suture, 53 mesh) who underwent primary total hip or knee arthroplasty between February 2017 and May 2018. Patients were divided into 3 closure groups: zipper device, monofilament suture plus adhesive, and monofilament plus polyester mesh with adhesive. The primary endpoint was closure time (superficial skin layer). Secondarily we collected perioperative complication rates, including infection, persistent (14-day) wound drainage, 90-day readmission, and emergency room visit rates as well as compared material costs.

resultsThere were no differences in baseline characteristics between groups for age, body mass index, and American Society of Anesthesiologists classification. There was a trend toward decreased time to closure for the suture group. There were no significant differences between groups for our secondary endpoint, complications.

conclusionsOur study shows that the suture group trended toward shorter closure time but suggests that each of the closure methods after total joint arthroplasty has equivalent complication rates. With small differences in closure time and no significant differences in complications, the decision to use one wound closure device or technique over another should be driven by institutional costs and provider familiarity.

Indexed as

MeshSuturesTotal hip arthroplastyTotal knee arthroplastyWound-closureZipper

Identifiers

PMID34136609
PMCPMC8180960
OpenAlexW3169181583

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.