Evidence map›Paper›PMID 34135419›Full record

ArticleScientific reports2021

Simulation-based optimisation to quantify heterogeneity of specific ventilation and perfusion in the lung by the Inspired Sinewave Test.

M C Tran, V Nguyen, R Bruce, D C Crockett, F Formenti, P A Phan, S J Payne, A D Farmery

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

M C TranInstitute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, UK. minh.tran@chch.ox.ac.uk.
V NguyenDepartment of Materials and Oxford-Man Institute of Quantitative Finance, University of Oxford, Oxford, OX2 6ED, UK.
R BruceCentre for Human and Applied Physiological Sciences, King's College London, London, SE1 9RT, UK.
D C CrockettNuffield Department of Clinical Neurosciences, John Radcliffe Hospital, Oxford, OX3 9DU, UK.
F FormentiNuffield Department of Clinical Neurosciences, John Radcliffe Hospital, Oxford, OX3 9DU, UK.
P A PhanNuffield Department of Clinical Neurosciences, John Radcliffe Hospital, Oxford, OX3 9DU, UK.
S J PayneInstitute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, UK.
A D FarmeryNuffield Department of Clinical Neurosciences, John Radcliffe Hospital, Oxford, OX3 9DU, UK.

Funding

Department of Health II-LA-0214- 20005Medical Research Council MC_PC_17164
6 · The paper itself

Abstract

The degree of specific ventilatory heterogeneity (spatial unevenness of ventilation) of the lung is a useful marker of early structural lung changes which has the potential to detect early-onset disease. The Inspired Sinewave Test (IST) is an established noninvasive 'gas-distribution' type of respiratory test capable of measuring the cardiopulmonary parameters. We developed a simulation-based optimisation for the IST, with a simulation of a realistic heterogeneous lung, namely a lognormal distribution of spatial ventilation and perfusion. We tested this method in datasets from 13 anaesthetised pigs (pre and post-lung injury) and 104 human subjects (32 healthy and 72 COPD subjects). The 72 COPD subjects were classified into four COPD phenotypes based on 'GOLD' classification. This method allowed IST to identify and quantify heterogeneity of both ventilation and perfusion, permitting diagnostic distinction between health and disease states. In healthy volunteers, we show a linear relationship between the ventilatory heterogeneity versus age ([Formula: see text]). In a mechanically ventilated pig, IST ventilatory heterogeneity in noninjured and injured lungs was significantly different (p < 0.0001). Additionally, measured indices could accurately identify patients with COPD (area under the receiver operating characteristic curve is 0.76, p < 0.0001). The IST also could distinguish different phenotypes of COPD with 73% agreement with spirometry.

Indexed as

AdultAgedAnimalsBayes TheoremCase-Control StudiesComputer SimulationFemaleHumansMaleMiddle AgedModels, AnimalPulmonary Disease, Chronic ObstructivePulmonary VentilationRespiratory Distress SyndromeRespiratory Function TestsSwine

Identifiers

PMID34135419
PMCPMC8208972

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.