Evidence map›Paper›PMID 34135305›Full record

ArticleLight, science & applications2021

Operando monitoring transition dynamics of responsive polymer using optofluidic microcavities.

Da-Quan Yang, Jin-Hui Chen, Qi-Tao Cao, Bing Duan, Hao-Jing Chen, Xiao-Chong Yu, Yun-Feng Xiao

Abstract read
In one paragraph

Article in Light, science & applications, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Ultrasound sensing with optical microcavities.Light, science & applications · 2024
    Review
  6. Article
  7. Article
  8. Multimode sensing based on optical microcavities.Frontiers of optoelectronics · 2023
    Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Single-molecule optofluidic microsensor with interface whispering gallery modes.Proceedings of the National Academy of Sciences of the United States of America · 2022
    Article
  15. Review
  16. Special Issue on the 60Light, science & applications · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Da-Quan Yang *School of Information and Communication Engineering, State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing, 100876, China.
Jin-Hui Chen *Institute of Electromagnetics and Acoustics, Xiamen University, Xiamen, 361005, China.
Qi-Tao Cao *State Key Laboratory for Mesoscopic Physics and Frontiers Science Center for Nano-optoelectronics, School of Physics, Peking University, Beijing, 100871, China.
Bing DuanSchool of Information and Communication Engineering, State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing, 100876, China.
Hao-Jing ChenState Key Laboratory for Mesoscopic Physics and Frontiers Science Center for Nano-optoelectronics, School of Physics, Peking University, Beijing, 100871, China.ORCID http://orcid.org/0000-0001-8907-3908
Xiao-Chong YuDepartment of Physics and Applied Optics Beijing Area Major Laboratory, Beijing Normal University, Beijing, 100875, China.
Yun-Feng XiaoState Key Laboratory for Mesoscopic Physics and Frontiers Science Center for Nano-optoelectronics, School of Physics, Peking University, Beijing, 100871, China. yfxiao@pku.edu.cn.ORCID http://orcid.org/0000-0002-0296-7130

Funding

National Natural Science Foundation of China (National Science Foundation of China) 11654003National Natural Science Foundation of China (National Science Foundation of China) 11825402
6 · The paper itself

Abstract

Optical microcavities have become an attractive platform for precision measurement with merits of ultrahigh sensitivity, miniature footprint and fast response. Despite the achievements of ultrasensitive detection, optical microcavities still face significant challenges in the measurement of biochemical and physical processes with complex dynamics, especially when multiple effects are present. Here we demonstrate operando monitoring of the transition dynamics of a phase-change material via a self-referencing optofluidic microcavity. We use a pair of cavity modes to precisely decouple the refractive index and temperature information of the analyte during the phase-transition process. Through real-time measurements, we reveal the detailed hysteresis behaviors of refractive index during the irreversible phase transitions between hydrophilic and hydrophobic states. We further extract the phase-transition threshold by analyzing the steady-state refractive index change at various power levels. Our technology could be further extended to other materials and provide great opportunities for exploring on-demand dynamic biochemical processes.

Identifiers

PMID34135305
PMCPMC8209048

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.