Evidence map›Paper›PMID 34134747›Full record

ArticleJournal of orthopaedic surgery and research2021

The EOS 3D imaging system reliably measures posterior tibial slope.

Andreas Hecker, Till D Lerch, Rainer J Egli, Emanuel F Liechti, Frank M Klenke

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Andreas HeckerDepartment of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland. andreas.hecker@insel.ch.ORCID http://orcid.org/0000-0002-4946-5517
Till D LerchUniversity Institute for Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Rainer J EgliUniversity Institute for Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Emanuel F LiechtiDepartment of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Frank M KlenkeDepartment of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
University of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOne of the values determined during the assessment of knee issues is the posterior tibial slope (PTS). A new option for measuring the PTS is the EOS 3D imaging system, which provides anteroposterior (AP) and lateral long leg radiographs (LLRs) using less radiation than a conventional LLR. We investigated the reliability of the EOS 3D imaging system with respect to PTS measurements.

methodsWe retrospectively searched our radiological database for patients who underwent an EOS scan and a computed tomography (CT) scan of their lower extremities between January and December 2019. Fifty-six knees were included in the study. Medial and lateral PTSs were determined using both modalities. A radiologist and an orthopaedic surgeon each performed all measurements twice and the intraclass correlation (ICC) was calculated to assess inter- and intrarater reliability. The Student t test and Pearson correlation were used to compare the results of both imaging modalities.

resultsThe mean medial PTS was 8.5° (95% confidence interval [CI], 8.1-8.9°) for the EOS system and 7.7° (95% CI, 7.3-8.1°) for CT, and the lateral PTS was 7.4° (95% CI, 6.9-7.9°) for the EOS system, and 7.0° (95% CI, 6.5-7.4°) for CT. Interrater reliability (ICC) with respect to medial and lateral PTSs measured on the EOS (0.880, 0.765) and CT (0.884, 0.887) images was excellent. The intrarater reliability of reader 1 (ICC range, 0.889-0.986) and reader 2 (ICC range, 0.868-0.980) with respect to the same measurements was excellent.

conclusionThe PTS measurements from the EOS 3D imaging system are as reliable and reproducible as those from CT, the current gold standard method. We recommend using this system if possible, because it acquires more information (sagittal plane) in a scan than a conventional LLR, while exposing the patient to less radiation. LEVEL OF EVIDENCE: Level III, Retrospective cohort study.

Indexed as

AdolescentAdultDatabases, FactualFemaleHumansImaging, Three-DimensionalMaleMiddle AgedReproducibility of ResultsRetrospective StudiesTibiaTomography, X-Ray ComputedYoung AdultEOSLong leg radiographsPlanning HTOSagittal lower leg alignmentTibial slope

Identifiers

PMID34134747
PMCPMC8207749
OpenAlexW3170224629

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.