ArticleJournal of orthopaedic surgery and research2021
The EOS 3D imaging system reliably measures posterior tibial slope.
Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 12 citations in OpenAlex.
- Comparison of coronal and sagittal pelvic-lower limb alignment after open wedge distal tibial tuberosity osteotomy and total knee arthroplasty using the EOS imaging system.Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology · 2026Article
- Posterior Tibial Slope Is Highly Variable and Asymmetric in Asian Osteoarthritic Knees: A Three-Dimensional CT Analysis.Journal of clinical medicine · 2026Article
- Radiographic Posterior Tibial Slope Measurement in Medial Unicompartmental Knee Arthroplasty: A Retrospective Validation Study Using Digital Volume Tomography of Tibial Resectates.Journal of clinical medicine · 2026Article
- A Whole-Spine Radiography Study to Reduce Patient Exposure Dose and Artifacts Using the EOS Imaging System.Bioengineering (Basel, Switzerland) · 2024Article
- Measurement of tibial slope using biplanar stereoradiography (EOS®).Skeletal radiology · 2024Article
- Deep learning-based identification of spine growth potential on EOS radiographs.European radiology · 2024Article
- The tibial tubercle-trochlear groove distance: a comparison study between EOS and MRI in the paediatric population.Skeletal radiology · 2024Article
- Changes in Parameters after High Tibial Osteotomy: Comparison of EOS System and Computed Tomographic Analysis.Journal of clinical medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundOne of the values determined during the assessment of knee issues is the posterior tibial slope (PTS). A new option for measuring the PTS is the EOS 3D imaging system, which provides anteroposterior (AP) and lateral long leg radiographs (LLRs) using less radiation than a conventional LLR. We investigated the reliability of the EOS 3D imaging system with respect to PTS measurements.
methodsWe retrospectively searched our radiological database for patients who underwent an EOS scan and a computed tomography (CT) scan of their lower extremities between January and December 2019. Fifty-six knees were included in the study. Medial and lateral PTSs were determined using both modalities. A radiologist and an orthopaedic surgeon each performed all measurements twice and the intraclass correlation (ICC) was calculated to assess inter- and intrarater reliability. The Student t test and Pearson correlation were used to compare the results of both imaging modalities.
resultsThe mean medial PTS was 8.5° (95% confidence interval [CI], 8.1-8.9°) for the EOS system and 7.7° (95% CI, 7.3-8.1°) for CT, and the lateral PTS was 7.4° (95% CI, 6.9-7.9°) for the EOS system, and 7.0° (95% CI, 6.5-7.4°) for CT. Interrater reliability (ICC) with respect to medial and lateral PTSs measured on the EOS (0.880, 0.765) and CT (0.884, 0.887) images was excellent. The intrarater reliability of reader 1 (ICC range, 0.889-0.986) and reader 2 (ICC range, 0.868-0.980) with respect to the same measurements was excellent.
conclusionThe PTS measurements from the EOS 3D imaging system are as reliable and reproducible as those from CT, the current gold standard method. We recommend using this system if possible, because it acquires more information (sagittal plane) in a scan than a conventional LLR, while exposing the patient to less radiation. LEVEL OF EVIDENCE: Level III, Retrospective cohort study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials