A compact and mobile hybrid C-arm scanner for simultaneous nuclear and fluoroscopic image guidance.

Martijn M A Dietze, Britt Kunnen, Frank Brontsema, Pascal Ramaekers, Casper Beijst, Maryam Afifah, Arthur J A T Braat, Marnix G E H Lam, Hugo W A M de Jong

Abstract read
In one paragraph

Article in European radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Optimization ofEJNMMI physics · 2025
    Article
  3. Article
  4. The potential of the Crystal Cam handheld gamma-camera for preoperative and intraoperative sentinel lymph node localization in early-stage oral cancer.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023
    Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Martijn M A DietzeRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands. m.m.a.dietze@umcutrecht.nl.ORCID http://orcid.org/0000-0003-1159-3510
Britt KunnenRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
Frank BrontsemaRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
Pascal RamaekersRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
Casper BeijstRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
Maryam AfifahRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
Arthur J A T BraatRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
Marnix G E H LamRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
Hugo W A M de JongRadiology and Nuclear Medicine, University Medical Center Utrecht and Utrecht University, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.

Funding

Horizon 2020 646734Horizon 2020 963934
6 · The paper itself

Abstract

purposeThis study evaluates the performance of a mobile and compact hybrid C-arm scanner (referred to as IXSI) that is capable of simultaneous acquisition of 2D fluoroscopic and nuclear projections and 3D image reconstruction in the intervention room.

resultsThe impact of slightly misaligning the IXSI modalities (in an off-focus geometry) was investigated for the reduction of the fluoroscopic and nuclear interference. The 2D and 3D nuclear image quality of IXSI was compared with a clinical SPECT/CT scanner by determining the spatial resolution and sensitivity of point sources and by performing a quantitative analysis of the reconstructed NEMA image quality phantom. The 2D and 3D fluoroscopic image of IXSI was compared with a clinical CBCT scanner by visualizing the Fluorad A+D image quality phantom and by visualizing a reconstructed liver nodule phantom. Finally, the feasibility of dynamic simultaneous nuclear and fluoroscopic imaging was demonstrated by injecting an anthropomorphic phantom with a mixture of iodinated contrast and

conclusionDue to the divergent innovative hybrid design of IXSI, concessions were made to the nuclear and fluoroscopic image qualities. Nevertheless, IXSI realizes unique image guidance that may be beneficial for several types of procedures. KEY POINTS: • IXSI can perform time-resolved planar (2D) simultaneous fluoroscopic and nuclear imaging. • IXSI can perform SPECT/CBCT imaging (3D) inside the intervention room.

Indexed as

Imaging, Three-DimensionalTomography, Emission-Computed, Single-PhotonCone-Beam Computed TomographyFluoroscopyHumansImage Processing, Computer-AssistedPhantoms, ImagingCone-beam CTFluoroscopyHybrid imagingScintigraphySPECT

Identifiers

PMID34132877
PMCPMC8660732

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.