ReviewEye (London, England)2021
Conventional glaucoma implants and the new MIGS devices: a comprehensive review of current options and future directions.
Review in Eye (London, England), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 60 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
60 citing papers in PubMed, 1 synthesis or guideline pooled it, 116 citations in OpenAlex.
- The efficacy of adjunctive mitomycin C and/or anti-VEGF agents on glaucoma tube shunt drainage device surgeries: a systematic review.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2024Pooled it
- Combined Phacoemulsification and STREAMLINE Surgical System Canal of Schlemm Transluminal Dilation in Eyes of Hispanic Patients with Mild to Moderate Glaucoma.Clinical ophthalmology (Auckland, N.Z.) · 2023Trial
- Paul glaucoma implant extrusion following post-surgical scleritis in patients with uveitic glaucoma: A case series.American journal of ophthalmology case reports · 2026Article
- Evaluation of iStent® Inject W in mild to moderate primary open-angle glaucoma - Indian data on pseudophakic eyes.Indian journal of ophthalmology · 2026Article
- Salvage of a severed Paul Glaucoma Implant tube via anastomosis with an Ahmed Glaucoma Valve in a child with Sturge-Weber syndrome and complicated glaucoma: a case report.International journal of surgery case reports · 2026Article
- ALKBH5 aggravates scarring after glaucoma surgery via mCell death and differentiation · 2026Article
- Sonography versus anterior segment OCT for imaging bleb morphology after glaucoma drainage device surgery.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026Article
- Toward Light-Responsive Hydrogel-Based Valves for Flow Regulation.Langmuir : the ACS journal of surfaces and colloids · 2026Article
- Baerveldt-350 with adjunctive goniotomy: One-year outcomes.American journal of ophthalmology case reports · 2026Article
- Clinical outcomes of the PAUL glaucoma implant in primary open-angle and pseudoexfoliative glaucoma eyes after failed glaucoma surgeries.Acta ophthalmologica · 2026Article
- Trabecular Meshwork-Based MIGS: Efficacy, Technique Variability, and Wound Healing-A Comprehensive Review.Journal of clinical medicine · 2026Review
- Clinical outcomes of the PAUL® Glaucoma implant for refractory glaucoma: three-year results.Eye (London, England) · 2026Article
- Adverse events associated with the subconjunctival Ex-Press® Glaucoma Filtration Device: a ten-year review of the MAUDE database.International ophthalmology · 2025Article
- Minimally Invasive Glaucoma Surgery: Is It Here to Stay?Clinical & experimental ophthalmology · 2025Review
- Real-World Data of the First UK Series of MINIject Supraciliary Glaucoma Implant with 6 Months Follow-Up.Ophthalmology and therapy · 2025Article
- Tube erosions following glaucoma drainage device implantations.Scientific reports · 2025Article
- Impact of the COVID-19 pandemic on glaucoma surgery in German hospitals.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025Article
- Inhibition of cGMP-Signalling Rescues Retinal Ganglion Cells From Axotomy-Induced Degeneration.Journal of neurochemistry · 2025Article
- Imaging of aqueous outflow in health and glaucoma. Justifying the re-direction of aqueous.Eye (London, England) · 2025Review
- [Learn playfully, operate seriously : The new era of surgical training].Chirurgie (Heidelberg, Germany) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Glaucoma is a progressive optic neuropathy that is the second leading cause of preventable blindness worldwide, after cataract formation. A rise in the intraocular pressure (IOP) is considered to be a major risk factor for glaucoma and is associated with an abnormal increase of resistance to aqueous humour outflow from the anterior chamber. Glaucoma drainage devices have been developed to provide an alternative pathway through which aqueous humour can effectively exit the anterior chamber, thereby reducing IOP. These devices include the traditional aqueous shunts with tube-plate design, as well as more recent implants, such as the trabeculectomy-modifying EX-PRESS
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.