ArticleEuropean heart journal. Case reports2021
Twiddler's syndrome after implantation of baroreflex activation therapy: a case report.
Article in European heart journal. Case reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTwiddler's syndrome is a rare complication after implantation of cardiac pacemakers or cardioverter-defibrillators that usually occurs within the first year after the procedure. However, it has not yet been described following implantation of baroreflex activation therapy (BAT). CASE SUMMARY: A 61-year-old female patient was referred to the cardiology outpatient clinic due to uncontrolled arterial hypertension despite maximal doses of several established drugs. Therefore, right-sided BAT implantation was successfully performed in February 2017 with good clinical response. Because of sustained neck pain at the site of stimulator, surgical revision was performed in November 2019 including a switch of the lead to the contralateral position. Approximately 1 month later, Twiddler's syndrome was identified on the basis of recurrent pain at the generator site necessitating pocket-revision, however, the lead was only untwisted but not replaced. A few weeks afterwards, unfortunately, lead revision was indispensable due to lead fracture. DISCUSSION: This case presents the uncommon phenomenon of Twiddler's syndrome after BAT implantation. In addition, the commonly twisted lead should always be replaced as well during surgical pocket-revision in order to ensure proper long-term function.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials