Evidence map›Paper›PMID 34122759›Full record

ArticleIndian journal of orthopaedics2021

Use of Acetate Templates Over Digital Radiographs for Templating in Total Hip Arthroplasty: Technique and Its Validation.

Tarun Goyal, Siddharth S Sethy, Sajid Ansari, Lakshmana Das, Souvik Paul

Open access · bronzeAbstract read
In one paragraph

Article in Indian journal of orthopaedics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Tarun GoyalDepartment of Orthopaedics, All India Institute of Medical Sciences, Bathinda, Punjab 151001 India.ORCID 0000-0002-1428-9947
Siddharth S SethyDepartment of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India.ORCID 0000-0002-4936-7896
Sajid AnsariDepartment of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India.ORCID 0000-0001-6935-4999
Lakshmana DasDepartment of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India.ORCID 0000-0002-2720-6389
Souvik PaulDepartment of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India.ORCID 0000-0002-1172-3664
All India Institute of Medical Sciences Rishikesh · INCentral University of Punjab · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAcetate templates were commonly used for templating for total hip arthroplasty. With digital radiographs having replaced conventional analogue radiographs, newer techniques are required. We describe a method for templating images of digital radiographs using conventional acetate templates, which is independent of a magnification marker or PACS system.

methodsFifty-one patients (64 hips) who were treated with primary THA were prospectively evaluated. Templating was done by keeping the acetate template directly over the digital image of the radiograph on a liquid crystal display (LCD) monitor, after calibrating the linear scale generated by the digital radiography machine. The size of prosthesis predicted on this templating technique was compared with the actual sizes used during the surgery. Inter-observer and intra-observer reliabilities were assessed. Our calibration method was further validated by comparing the size of the cup calculated on postoperative radiograph using digital templating software (mediCAD Hectec GmbH) and the actual size used during surgery.

resultsAccurate size was predicted for 36.7% of the acetabular cup and 35.9% of femoral stems. The accuracy within ± one size was 89.9% for acetabular cups and 91.4% for femoral stems. Excellent inter-observer and intra-observer reliability were seen for both femoral and acetabular components.

conclusionThe method described provides an accurate, reproducible, convenient and low-cost technique of preoperative templating. It combines the ease of using acetate templates with the convenience of being able to use digital images, without the need for expensive software.

Indexed as

Digital radiographTemplatingTotal hip arthroplasty

Identifiers

PMID34122759
PMCPMC8149513
OpenAlexW3097887156

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.