Evidence map›Paper›PMID 34120237›Full record

ArticleArchives of orthopaedic and trauma surgery2022

Do hip-abduction braces work?-A biomechanical evaluation of a commercially available hip brace.

Roman Michalik, Katrin Essing, Ben Rohof, Matthias Gatz, Filippo Migliorini, Marcel Betsch

Open access · hybridAbstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Roman MichalikDepartment of Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany. rmichalik@ukaachen.de.ORCID http://orcid.org/0000-0002-9431-0637
Katrin EssingDepartment of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.
Ben RohofDepartment of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.
Matthias GatzDepartment of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.
Filippo MiglioriniDepartment of Orthopaedic Surgery, University Hospital RWTH Aachen, Aachen, Germany.
Marcel BetschDepartment of Orthopaedics and Trauma Surgery, University Medical Center Mannheim of the University Heidelberg, Mannheim, Germany.
RWTH Aachen University · DEHeidelberg University · DEUniversitätsklinikum Aachen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDislocations of the hip joint are a common and clinically relevant complication following total hip arthroplasty (THA). Hip-abduction braces are currently used following operative or non-operative treatment of THA dislocations to prevent re-dislocations. However, the clinical and biomechanical effectiveness of such braces is still controversial. MATERIAL AND

methodsA total of 30 volunteers were measured during standing and during sitting up and down from a chair task wearing a hip brace set at 70°, 90° or no hip flexion limitation. Range of motion of the hip joint was measured in all directions by an inertial sensor system. Further it has been evaluated if the range of motion would be reduced by the additional use of an arthrodesis cushion.

resultsThe use of a hip brace set up with flexion limitation did reduce hip ROM in all directions significantly compared to unhinged brace (p < 0.001-0.035). Performing the "sit down and stand-up task" the brace set up at 70° flexion limitation did reduce maximum hip flexion significantly (p = 0.008). However, in most cases the measured hip flexion angles were greater than the settings of the hip brace should have allowed. The additional use of a cushion can further limit hip motion while sitting up and down from a chair.

conclusionThis study has demonstrated that hip-abduction braces reduce hip range of motion. However, we also found that to achieve a flexion limitation of the hip to 90°, the hip brace should be set at a 70° hip flexion limitation.

Indexed as

Arthroplasty, Replacement, HipBracesBiomechanical PhenomenaHip JointHumansRange of Motion, ArticularArthrodesis cushionHip braceHip dislocationInertial sensorsTotal hip arthroplasty

Identifiers

PMID34120237
PMCPMC9110475
OpenAlexW3170003405

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.