Evidence map›Paper›PMID 34117921›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2022

The instep flap for anterior ankle coverage with bone and hardware exposure.

Ali Hassan Chamseddine, Abbas A Dib, Hassan M Wardani

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Ali Hassan ChamseddineDivision of Orthopaedic and Trauma Surgery, Sahel General Hospital, University Medical Centre, PO Box 99/25., Ghoubeiry, Beirut, Lebanon. achamsedine@hotmail.com.ORCID http://orcid.org/0000-0003-4649-1522
Abbas A DibDivision of Orthopaedic and Trauma Surgery, Sahel General Hospital, University Medical Centre, PO Box 99/25., Ghoubeiry, Beirut, Lebanon.
Hassan M WardaniDivision of Orthopaedic and Trauma Surgery, Sahel General Hospital, University Medical Centre, PO Box 99/25., Ghoubeiry, Beirut, Lebanon.
Rafik Hariri University Hospital · LB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe instep medial plantar flap is a well-known flap based on the medial plantar artery of the foot and usually used for coverage of soft tissue defects of the heel area. It has seldom been reported for coverage of anterior ankle area with exposure of the bone and metallic hardware after open reduction and internal fixation of distal tibial fractures. The primary purpose of this study is to evaluate the feasibility and viability of this flap as well as its reliability saving the internal fixation devices and efficiency protecting bone healing; the secondary purpose is to assess the condition of the flap and its cosmetic appearance, as well as occurrence of complications related to its harvesting. MATERIAL AND

methodsThis is a retrospective review of medical records of patients operated from December 2015 to December 2020 with application of an instep flap for coverage of the anterior ankle area with exposure of the bone and metallic hardware secondary to open reduction and internal fixation of distal tibial fractures. All patients were reviewed for the purpose of this study; they were assessed for the viability and functional and sensory condition of the flap, signs of local infection, as well as for residual pain and sensory impairment of the toes; subjective cosmetic appearance of the flap was also judged.

resultsThere were four patients with 32 years mean age and 35 months mean follow-up. The mean flap size was 7.75 cm × 5.75 cm. At final follow-up, all fractures were completely consolidated, and all flaps were living, stable, and sensitive. No distal sensation disturbance was noticed, and none of the patients had pain or annoyance caused by the flap or presented signs of infection. Only one patient expressed mild aesthetic complain.

conclusionThe fascio-cutaneous instep medial plantar flap is a reliable solution to cover the anterior ankle area with exposure of the bone and metallic hardware after open reduction and internal fixation of distal tibial fractures, especially for defects measuring up to 9 cm × 6 cm. This flap is technically valid and reproducible; it offers good quality of soft tissue coverage with satisfactory cosmetic appearance and minimal morbidity.

Indexed as

Plastic Surgery ProceduresSoft Tissue InjuriesTibial FracturesAdultAnkleHumansPainReproducibility of ResultsInstep flapMedial plantar flapORIF distal tibial fracturesSoft tissue defect of the ankle

Identifiers

PMID34117921
OpenAlexW3166348271

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.