ArticleMagnetic resonance imaging2021
Feasibility of MR fingerprinting using a high-performance 0.55 T MRI system.
Article in Magnetic resonance imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 28 citations in OpenAlex.
- An evaluation of brain volume and cortical thickness measurement at 0.55 T.Magma (New York, N.Y.) · 2026Article
- 3D Whole-Heart Joint TNMR in biomedicine · 2026Article
- Acceleration of slice encoding for metal artifact correction at 0.55 T using hexagonal sampling.Magnetic resonance in medicine · 2026Article
- Three-dimensional high-isotropic-resolution MR fingerprinting optimized for 0.55 T.Magnetic resonance in medicine · 2025Article
- MRI at low field: A review of software solutions for improving SNR.NMR in biomedicine · 2025Review
- Feasibility of 3D MRI fingerprinting for rapid knee cartilage TNMR in biomedicine · 2024Article
- Assessment of the Diagnostic Efficacy of Low-Field Magnetic Resonance Imaging: A Systematic Review.Diagnostics (Basel, Switzerland) · 2024Review
- Emerging Trends in Magnetic Resonance Fingerprinting for Quantitative Biomedical Imaging Applications: A Review.Bioengineering (Basel, Switzerland) · 2024Review
- Cardiac MRI at Low Field Strengths.Journal of magnetic resonance imaging : JMRI · 2024Review
- Low-field MRI: A report on the 2022 ISMRM workshop.Magnetic resonance in medicine · 2023Review
- Tackling SNR at low-field: a review of hardware approaches for point-of-care systems.Magma (New York, N.Y.) · 2023Review
- Assessment of MRF for simultaneous TMagma (New York, N.Y.) · 2023Article
- Low-field MRI: Clinical promise and challenges.Journal of magnetic resonance imaging : JMRI · 2023Review
- Technical overview of magnetic resonance fingerprinting and its applications in radiation therapy.Medical physics · 2022Review
- Feasibility of Magnetic Resonance Fingerprinting on Aging MRI Hardware.Tomography (Ann Arbor, Mich.) · 2021Article
- Toward magnetic resonance fingerprinting for low-field MR-guided radiation therapy.Medical physics · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
Abstract
backgroundMR fingerprinting (MRF) is a versatile method for rapid multi-parametric quantification. The application of MRF for lower MRI field could enable multi-contrast imaging and improve exam efficiency on these systems. The purpose of this work is to demonstrate the feasibility of 3D whole-brain T1 and T2 mapping using MR fingerprinting on a contemporary 0.55 T MRI system. MATERIALS AND
methodsA 3D whole brain stack-of-spirals FISP MRF sequence was implemented for 0.55 T. Quantification was validated using the NIST/ISMRM Quantitative MRI phantom, and T1 and T2 values of white matter, gray matter, and cerebrospinal fluid were measured in 19 healthy subjects. To assess MRF performance in the lower SNR regime of 0.55 T, measurement precision was calculated from 100 simulated pseudo-replicas of in vivo data and within-session measurement repeatability was evaluated.
resultsT1 and T2 values calculated by MRF were strongly correlated to standard measurements in the ISMRM/NIST MRI system phantom (R
conclusionA 3D whole-brain stack-of-spirals FISP MRF sequence is feasible for T1 and T2 mapping at 0.55 T.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.