Evidence map›Paper›PMID 34113656›Full record

ArticleFrontiers in robotics and AI2021

Autonomous Robotic Point-of-Care Ultrasound Imaging for Monitoring of COVID-19-Induced Pulmonary Diseases.

Lidia Al-Zogbi, Vivek Singh, Brian Teixeira, Avani Ahuja, Pooyan Sahbaee Bagherzadeh, Ankur Kapoor, Hamed Saeidi, Thorsten Fleiter, Axel Krieger

Open access · goldAbstract read
In one paragraph

Article in Frontiers in robotics and AI, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Lidia Al-ZogbiLaboratory for Computational Sensing and Robotics, Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States.
Vivek SinghMedical Imaging Technologies, Siemens Medical Solutions, Inc. USA, Princeton, NJ, United States.
Brian TeixeiraMedical Imaging Technologies, Siemens Medical Solutions, Inc. USA, Princeton, NJ, United States.
Avani AhujaGeorgetown Day High School, WA, DC, United States.
Pooyan Sahbaee BagherzadehMedical Imaging Technologies, Siemens Medical Solutions, Inc. USA, Princeton, NJ, United States.
Ankur KapoorMedical Imaging Technologies, Siemens Medical Solutions, Inc. USA, Princeton, NJ, United States.
Hamed SaeidiLaboratory for Computational Sensing and Robotics, Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States.
Thorsten FleiterR. Cowley Shock Trauma Center, Department of Diagnostic Radiology, School of Medicine, University of Maryland, Baltimore, MD, United States.
Axel KriegerLaboratory for Computational Sensing and Robotics, Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States.
Siemens (United States) · USJohns Hopkins University · USGeorgetown College · USUniversity of Maryland, Baltimore · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The COVID-19 pandemic has emerged as a serious global health crisis, with the predominant morbidity and mortality linked to pulmonary involvement. Point-of-Care ultrasound (POCUS) scanning, becoming one of the primary determinative methods for its diagnosis and staging, requires, however, close contact of healthcare workers with patients, therefore increasing the risk of infection. This work thus proposes an autonomous robotic solution that enables POCUS scanning of COVID-19 patients' lungs for diagnosis and staging. An algorithm was developed for approximating the optimal position of an ultrasound probe on a patient from prior CT scans to reach predefined lung infiltrates. In the absence of prior CT scans, a deep learning method was developed for predicting 3D landmark positions of a human ribcage given a torso surface model. The landmarks, combined with the surface model, are subsequently used for estimating optimal ultrasound probe position on the patient for imaging infiltrates. These algorithms, combined with a force-displacement profile collection methodology, enabled the system to successfully image all points of interest in a simulated experimental setup with an average accuracy of 20.6 ± 14.7 mm using prior CT scans, and 19.8 ± 16.9 mm using only ribcage landmark estimation. A study on a full torso ultrasound phantom showed that autonomously acquired ultrasound images were 100% interpretable when using force feedback with prior CT and 88% with landmark estimation, compared to 75 and 58% without force feedback, respectively. This demonstrates the preliminary feasibility of the system, and its potential for offering a solution to help mitigate the spread of COVID-19 in vulnerable environments.

Indexed as

3D deep convolutional network3D landmark estimationautonomous roboticsCOVID-19force feedbackpoint-of-care ultrasound

Identifiers

PMID34113656
PMCPMC8185340
OpenAlexW3165097438

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.