Evidence map›Paper›PMID 34113608›Full record

ArticleFrontiers in physics2020

Protocols for Dual Tracer PET/SPECT Preclinical Imaging.

Julia E Blower, Jayanta K Bordoloi, Alex Rigby, Matthew Farleigh, Jana Kim, Hugh O'Brien, Jonathan Jackson, Constantinos Poyiatzis, James Bezer, Kavitha Sunassee and 2 more

Open access · goldAbstract read
In one paragraph

Article in Frontiers in physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Multiplexed imaging of radionuclides.Nature biomedical engineering · 2025
    Review
  3. Influence of spill-over forPhysical and engineering sciences in medicine · 2024
    Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 1 country.

Julia E BlowerSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Jayanta K BordoloiSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Alex RigbySchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Matthew FarleighSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Jana KimSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Hugh O'BrienSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Jonathan JacksonSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Constantinos PoyiatzisSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
James BezerSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Kavitha SunasseeSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Philip J BlowerSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
Lefteris LivieratosSchool of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.
King's College London · GBSt Thomas' Hospital · GB

Funding

Wellcome Trust 203148Wellcome Trust 203148/Z/16/Z
6 · The paper itself

Abstract

backgroundMulti-tracer PET/SPECT imaging enables different modality tracers to be present simultaneously, allowing multiple physiological processes to be imaged in the same subject, within a short time-frame. Fluorine-18 and technetium-99m, two commonly used PET and SPECT radionuclides, respectively, possess different emission profiles, offering the potential for imaging one in the presence of the other. However, the impact of the presence of each radionuclide on scanning the other could be significant and lead to confounding results. Here we use combinations of

methodsMixed-radionuclide

resultsPET scan image quality and quantification were adversely affected by

conclusionSuitable combinations of injection sequence and imaging sequence can be devised to meet specific experimental multi-tracer imaging needs, with only minor or insignificant effects of each radionuclide on the scan of the other.

Indexed as

dead-timedual-radionuclidemulti-modalityPETphantomradionuclidescatterSPECT

Identifiers

PMID34113608
PMCPMC7610950
OpenAlexW3021086019

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390