Evidence map›Paper›PMID 34113157›Full record

ArticleInternational journal of general medicine2021

The Short-Term Patency Rate of a Saphenous Vein Bridge Using the No-Touch Technique in off-Pump Coronary Artery Bypass Grafting in Vein Harvesting.

Teng-Yue Zhao, Ji-Qiang Bu, Jian-Jun Gu, Yu Liu, Wen-Li Zhang, Zi-Ying Chen

Open access · goldAbstract read
In one paragraph

Article in International journal of general medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Teng-Yue Zhao *Department of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, People's Republic of China.
Ji-Qiang Bu *Department of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, People's Republic of China.
Jian-Jun GuDepartment of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, People's Republic of China.
Yu LiuDepartment of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, People's Republic of China.
Wen-Li ZhangDepartment of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, People's Republic of China.
Zi-Ying ChenDepartment of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, People's Republic of China.
Hebei Medical University · CNSecond Hospital of Hebei Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to examine the short-term effect of the no-touch technique on the patency rate of a great saphenous vein (GSV) bridge used during off-pump coronary artery bypass grafting (OPCABG).

methodsBetween June 2018 and September 2020, 140 patients undergoing OPCABG, with grafts obtained from the GSV using the "no-touch" technique or the left internal mammary artery (LIMA), were enrolled in this study. The early clinical results and short-term patency rate of the OPCABG were evaluated at a three-month follow-up by comparing the patency rate of the LIMA bridge and the GSV bridge obtained by the no-touch technique. This study also analyzed the impacts of the postoperative complications of the lower limbs and the distribution area of diseased vessels on the patency rate of a GSV bridge obtained by the no-touch technique at an early stage.

resultsNo perioperative death or adverse cardiovascular or cerebrovascular events occurred in the 140 patients undergoing OPCABG. The difference in the early patency rate between the GSV bridge obtained by the no-touch technique and the LIMA bridge was not statistically significant (95.9% vs 97.1%, p = 0.501). There was no significant difference in the patency rate between an end-to-side anastomosed venous bridge and a LIMA bridge (95.0% [248/261] vs 97.1% [136/140], p = 0.314). The overall patency rate of a no-touch vein bridge in the right coronary artery region was lower than it was in the left coronary artery region (93.8% [165/176] vs 97.9% [183/187], p = 0.049).

conclusionThe no-touch technique may improve the early patency rate of a GSV bridge, and its effect is similar to that of a LIMA bridge.

Indexed as

great saphenous veinleft internal mammary arteryno-touch techniqueoff-pump coronary artery bypass grafting

Identifiers

PMID34113157
PMCPMC8184136
OpenAlexW3170795161

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.