Evidence map›Paper›PMID 34113081›Full record

ArticleDrug design, development and therapy2021

Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients.

Baitha Palanggatan Maggadani, Harmita, Samuel J Haryono, Marcellino Ryan Rinaldi, Yahdiana Harahap

Open access · goldAbstract readValidation Study
In one paragraph

Article in Drug design, development and therapy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Journal of personalized medicine · 2025
    Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Baitha Palanggatan MaggadaniFaculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia.
HarmitaFaculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia.
Samuel J HaryonoSurgical Oncology Division, MRCCC Siloam Hospital, Jakarta, Indonesia.ORCID 0000-0003-4045-347X
Marcellino Ryan RinaldiFaculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia.
Yahdiana HarahapFaculty of Pharmacy, Universitas Indonesia, Depok, 16424, Indonesia.ORCID 0000-0002-7217-7900
University of Indonesia · IDSiloam Eye Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn this research, we used a volumetric absorptive microsampling (VAMS) technique to collect blood samples from the patients. A rapid and simple sample preparation method and LC-MS.MS assay was then developed and validated for the simultaneous analysis of tamoxifen and its three active metabolites.

methodsVAMS extraction was performed in methanol by sonication-assisted extraction method for 25 min after 2 hof VAMS drying. Separation was carried out using Acquity UPLC BEH C RESULTS AND DISCUSSION: The lower limit of quantification value (LLOQ) was 2.50 ng/mL for tamoxifen, 2.50 ng/mL for endoxifen, 1.50 ng/mL for 4-hydroxitamoxifen, and 2.00 ng/mL for N-desmethyltamoxifen. Accuracy (%bias) and precision (%CV) were within 20% for LLOQ and 15% for other concentrations. There were no interference responses >20% of the LLOQ and 5% of the internal standard. The level of ion suppression in all analytes was less than 7%. The preparation system developed in this study successfully extracted more than 90% of analytes from the matrix with precision below 15%. Carryover was shown to be below 6% in all analytes. Stability of analytes in VAMS was demonstrated for up to 30 days, under room temperature storage in a sealed plastic bag with desiccant. This method was successfully applied to analyze tamoxifen and the metabolites level in 30 ER+ breast cancer patients.

Indexed as

Antineoplastic Agents, HormonalBreast NeoplasmsChromatography, High Pressure LiquidDrug MonitoringFemaleHumansReproducibility of ResultsTamoxifenTandem Mass SpectrometryTime Factors4-hydroxy-N-desmethyltamoxifenafimoxifeneAntineoplastic Agents, HormonalN-desmethyltamoxifenTamoxifenestrogen receptormethod developmentUPLC-MSMSvalidationVAMS

Identifiers

PMID34113081
PMCPMC8187001
OpenAlexW3167464043

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.