ArticleBiomedical engineering online2021

In vitro delivery efficiencies of nebulizers for different breathing patterns.

Hyun Mok Park, Kyung Hwa Chang, Sang-Hyub Moon, Bong Joo Park, Sun Kook Yoo, Ki Chang Nam

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Hyun Mok ParkDepartment of Medical Engineering, Dongguk University College of Medicine, Goyang, South Korea.
Kyung Hwa ChangDepartment of Medical Engineering, Dongguk University College of Medicine, Goyang, South Korea.
Sang-Hyub MoonDepartment of Medical Engineering, Dongguk University College of Medicine, Goyang, South Korea.
Bong Joo ParkDepartment of Electrical & Biological Physics, Kwangwoon University, Seoul, South Korea.
Sun Kook YooGraduate Program of Biomedical Engineering, Yonsei University, Seoul, South Korea. sunkyoo@yuhs.ac.
Ki Chang NamDepartment of Medical Engineering, Dongguk University College of Medicine, Goyang, South Korea. chadol@dongguk.ac.kr.ORCID http://orcid.org/0000-0002-0484-7845
Yonsei University · KRDongguk University · KRKwangwoon University · KR

Funding

National Research Foundation (KR) 2020R1A2C1101048
6 · The paper itself

Abstract

backgroundNebulizers are medical devices that deliver aerosolized medication directly to lungs to treat a variety of respiratory diseases. However, breathing patterns, respiration rates, airway diameters, and amounts of drugs delivered by nebulizers may be respiratory disease dependent.

methodIn this study, we developed a respiratory simulator consisting of an airway model, an artificial lung, a flow sensor, and an aerosol collecting filter. Various breathing patterns were generated using a linear actuator and an air cylinder. We tested six home nebulizers (jet (2), static (2), and vibrating mesh nebulizers (2)). Nebulizers were evaluated under two conditions, that is, for the duration of nebulization and at a constant output 1.3 mL using four breathing patterns, namely, the breathing pattern specified in ISO 27427:2013, normal adult, asthmatic, and COPD.

resultsOne of the vibrating mesh nebulizers had the highest dose delivery efficiency. The drug delivery efficiencies of nebulizers were found to depend on breathing patterns.

conclusionWe suggest a quantitative drug delivery efficiency evaluation method and calculation parameters that include considerations of constant outputs and residual volumes. The study shows output rates and breathing patterns should be considered when the drug delivery efficiencies of nebulizers are evaluated.

Indexed as

Drug Delivery SystemsNebulizers and VaporizersRespirationAdministration, InhalationAerosolsEquipment DesignHumansAerosolsDosageDrug deliveryEfficiencyNebulizerRespiratory simulator

Identifiers

PMID34112170
PMCPMC8194228
OpenAlexW3171806753

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.