Evidence map›Paper›PMID 34109769›Full record

ArticleJournal of biomedical optics2021

Quantitative dynamic near-infrared fluorescence imaging using indocyanine green for analysis of bowel perfusion after mesenteric resection.

Ruben P J Meijer, Labrinus van Manen, Henk H Hartgrink, Jacobus Burggraaf, Sylvain Gioux, Alexander L Vahrmeijer, J Sven D Mieog

Abstract readLetter
In one paragraph

Article in Journal of biomedical optics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Observational
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ruben P J MeijerLeiden University Medical Center, Department of Surgery, Leiden, The Netherlands.
Labrinus van ManenLeiden University Medical Center, Department of Surgery, Leiden, The Netherlands.
Henk H HartgrinkLeiden University Medical Center, Department of Surgery, Leiden, The Netherlands.
Jacobus BurggraafLeiden University Medical Center, Department of Surgery, Leiden, The Netherlands.
Sylvain GiouxUniversity of Strasbourg, ICube Laboratory, Strasbourg, France.
Alexander L VahrmeijerLeiden University Medical Center, Department of Surgery, Leiden, The Netherlands.
J Sven D MieogLeiden University Medical Center, Department of Surgery, Leiden, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceNear-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has proven to be a feasible application for real-time intraoperative assessment of tissue perfusion, although quantification of NIR fluorescence signals is pivotal for standardized assessment of tissue perfusion.

aimFour patients are described with possible compromised bowel perfusion after mesenteric resection. Based on these patients we want to emphasize the difficulties in the quantification of NIR fluorescence imaging for perfusion analysis. APPROACH: During image-guided fluorescence assessment, 5 mg of ICG (2.5  mg  /  ml) was intravenously administered by the anesthesiologist. NIR fluorescence imaging was done with the open camera system of Quest Medical Imaging. Fluorescence data taken from the regions of interest (bowel at risk, transition zone of bowel at risk and adjacent normally perfused bowel, and normally perfused reference bowel) were quantitatively analyzed after surgery for fluorescence intensity-and perfusion time-related parameters.

resultsBowel perfusion, as assessed clinically by independent surgeons based on NIR fluorescence imaging, resulted in different treatment strategies, three with excellent clinical outcome, but one with a perfusion related complication. Post-surgery quantitative analysis of fluorescence dynamics showed different patterns in the affected bowel segment compared to the unaffected reference segments for the four patients.

conclusionsSimilar intraoperative fluorescence results could lead to different surgical treatment strategies, which demonstrated the difficulties in interpretation of uncorrected fluorescence signals. Real-time quantification and standardization of NIR fluorescence perfusion imaging could probably aid surgeons in the nearby future.

Indexed as

Indocyanine GreenOptical ImagingAnastomosis, SurgicalFluorescenceHumansIntestinesPerfusionIndocyanine Greenbowel perfusionindocyanine greenmesenteric resectionnear infrared fluorescence

Identifiers

PMID34109769
PMCPMC8189572

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.