Evidence map›Paper›PMID 34106467›Full record

SynthesisThe Cochrane database of systematic reviews2021

Sentinel node biopsy for diagnosis of lymph node involvement in endometrial cancer.

Hans Nagar, Nina Wietek, Richard J Goodall, Will Hughes, Mia Schmidt-Hansen, Jo Morrison

Open access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed, 4 pooled it
8.6field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

41 citing papers in PubMed, 4 syntheses or guidelines pooled it, 69 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Trial
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Advanced Image-Guidance and Surgical-Navigation Techniques for Real-Time Visualized Surgery.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  12. Article
  13. Article
  14. Assessing para-aortic nodal status in high-grade endometrial cancer patients with negative pelvic sentinel lymph node biopsy.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2025
    Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 6 institutions in 1 country.

Hans NagarBelfast Health and Social Care Trust, Belfast City Hospital and the Royal Maternity Hospital, Belfast, UK.
Nina WietekNuffield Department of Women's & Reproductive Health, University of Oxford, Oxford, UK.
Richard J GoodallDepartment of Surgery and Cancer , Imperial College London, London, UK.
Will HughesDepartment of Plastic Surgery, Addenbrookes Hospital, Cambridge, UK.
Mia Schmidt-HansenNational Guideline Alliance, Royal College of Obstetricians and Gynaecologists, London, UK.
Jo MorrisonDepartment of Gynaecological Oncology, GRACE Centre, Musgrove Park Hospital, Taunton, UK.
Addenbrooke's Hospital · GBImperial College London · GBMusgrove Park Hospital · GBRoyal College of Obstetricians and Gynaecologists · GBUniversity of Oxford · GBUniversity of Ulster · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPelvic lymphadenectomy provides prognostic information for those diagnosed with endometrial (womb) cancer and provides information that may influence decisions regarding adjuvant treatment. However, studies have not shown a therapeutic benefit, and lymphadenectomy causes significant morbidity. The technique of sentinel lymph node biopsy (SLNB), allows the first draining node from a cancer to be identified and examined histologically for involvement with cancer cells. SLNB is commonly used in other cancers, including breast and vulval cancer. Different tracers, including colloid labelled with radioactive technetium-99, blue dyes, e.g. patent or methylene blue, and near infra-red fluorescent dyes, e.g. indocyanine green (ICG), have been used singly or in combination for detection of sentinel lymph nodes (SLN).

objectivesTo assess the diagnostic accuracy of sentinel lymph node biopsy (SLNB) in the identification of pelvic lymph node involvement in women with endometrial cancer, presumed to be at an early stage prior to surgery, including consideration of the detection rate. SEARCH

methodsWe searched MEDLINE (1946 to July 2019), Embase (1974 to July 2019) and the relevant Cochrane trial registers. SELECTION CRITERIA: We included studies that evaluated the diagnostic accuracy of tracers for SLN assessment (involving the identification of a SLN plus histological examination) against a reference standard of histological examination of removed pelvic +/- para-aortic lymph nodes following systematic pelvic +/- para-aortic lymphadenectomy (PLND/PPALND) in women with endometrial cancer, where there were sufficient data for the construction of two-by-two tables. DATA COLLECTION AND ANALYSIS: Two review authors (a combination of HN, JM, NW, RG, and WH) independently screened titles and abstracts for relevance, classified studies for inclusion/exclusion and extracted data. We assessed the methodological quality of studies using the QUADAS-2 tool. We calculated the detection rate as the arithmetic mean of the total number of SLNs detected out of the total number of women included in the included studies with the woman as the unit of analysis, used univariate meta-analytical methods to estimate pooled sensitivity estimates, and summarised the results using GRADE. MAIN

resultsThe search revealed 6259 unique records after removal of duplicates. After screening 232 studies in full text, we found 73 potentially includable records (for 52 studies), although we were only able to extract 2x2 table data for 33 studies, including 2237 women (46 records) for inclusion in the review, despite writing to trial authors for additional information. We found 11 studies that analysed results for blue dye alone, four studies for technetium-99m alone, 12 studies that used a combination of blue dye and technetium-99m, nine studies that used indocyanine green (ICG) and near infra-red immunofluorescence, and one study that used a combination of ICG and technetium-99m. Overall, the methodological reporting in most of the studies was poor, which resulted in a very large proportion of 'unclear risk of bias' ratings. Overall, the mean SLN detection rate was 86.9% (95% CI 82.9% to 90.8%; 2237 women; 33 studies; moderate-certainty evidence). In studies that reported bilateral detection the mean rate was 65.4% (95% CI 57.8% to 73.0%) . When considered according to which tracer was used, the SLN detection rate ranged from 77.8% (95% CI 70.0% to 85.6%) for blue dye alone (559 women; 11 studies; low-certainty evidence) to 100% for ICG and technetium-99m (32 women; 1 study; very low-certainty evidence). The rates of positive lymph nodes ranged from 5.2% to 34.4% with a mean of 20.1% (95% CI 17.7% to 22.3%). The pooled sensitivity of SLNB was 91.8% (95% CI 86.5% to 95.1%; total 2237 women, of whom 409 had SLN involvement; moderate-certainty evidence). The sensitivity for of SLNB for the different tracers were: blue dye alone 95.2% (95% CI 77.2% to 99.2%; 559 women; 11 studies; low-certainty evidence); Technetium-99m alone 90.5% (95% CI 67.7% to 97.7%; 257 women; 4 studies; low-certainty evidence); technetium-99m and blue dye 91.9% (95% CI 74.4% to 97.8%; 548 women; 12 studies; low-certainty evidence); ICG alone 92.5% (95% CI 81.8% to 97.1%; 953 women; 9 studies; moderate-certainty evidence); ICG and blue dye 90.5% (95% CI 63.2.6% to 98.1%; 215 women; 2 studies; low-certainty evidence); and ICG and technetium-99m 100% (95% CI 63% to 100%; 32 women; 1 study; very low-certainty evidence). Meta-regression analyses found that the sensitivities did not differ between the different tracers used, between studies with a majority of women with FIGO stage 1A versus 1B or above; between studies assessing the pelvic lymph node basin alone versus the pelvic and para-aortic lymph node basin; or between studies that used subserosal alone versus subserosal and cervical injection. It should be noted that a false-positive result cannot occur, as the histological examination of the SLN is unchanged by the results from any additional nodes removed at systematic lymphadenectomy. AUTHORS'

conclusionsThe diagnostic test accuracy for SLNB using either ICG alone or a combination of a dye (blue or ICG) and technetium-99m is probably good, with high sensitivity, where a SLN could be detected. Detection rates with ICG or a combination of dye (ICG or blue) and technetium-99m may be higher. The value of a SLNB approach in a treatment pathway, over adjuvant treatment decisions based on uterine factors and molecular profiling, requires examination in a high-quality intervention study.

Indexed as

Coloring AgentsEndometrial NeoplasmsFemaleFluorescent Antibody TechniqueHumansIndocyanine GreenLymph Node ExcisionLymph NodesPelvisRadioactive TracersSentinel Lymph Node BiopsySpectroscopy, Near-InfraredTechnetiumColoring AgentsIndocyanine GreenRadioactive TracersTechnetium

Identifiers

PMID34106467
PMCPMC8189170
OpenAlexW2801949246

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.