ArticleAIP advances2021
Nanowaveguide-illuminated fluorescence correlation spectroscopy for single molecule studies.
Article in AIP advances, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Fluorescence Correlation Spectroscopy (FCS) is a method of investigating concentration fluctuations of fluorescent particles typically in the nM range as a result of its femtoliter-sized sample volume. However, biological processes on cell membranes that involve molecules in the μM concentration range require sample volumes well below the conventional FCS limit as well as nanoscale confinement in the longitudinal direction. In this study, we show that an effective measurement volume down to the zeptoliter range can be achieved via the introduction of a nanowire waveguide, resulting in an illumination spot of about 50 nm in lateral dimensions and a longitudinal confinement of around 20 nm just above the waveguide exit surface. Using illumination profiles obtained from finite element method simulations of dielectric nanowaveguides, we perform Monte Carlo simulations of fluorescence fluctuations for two scenarios of fluorophore movement: fluorophores freely diffusing in the three-dimensional (3D) space above the nanowaveguide and fluorophores moving in a two-dimensional (2D) membrane situated directly above the nanowaveguide exit surface. We have developed analytical functions to fit the simulation results and found that an effective illumination size of about 150 zl and 4 × 10
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.