Evidence map›Paper›PMID 34104170›Full record

ArticlePakistan journal of medical sciences

Evaluation of the implant diameter on the initial-stability of narrow- and standard-diameter implants placed in simulated Type-I and Type-IV bone-blocks.

Saad Alresayes, Sameer A Mokeem, Aasem M Alhenaki, Fahim Vohra, Tariq Abduljabbar

Open access · goldAbstract read
In one paragraph

Article in Pakistan journal of medical sciences. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Saad AlresayesSaad Alresayes, BDS Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
Sameer A MokeemSameer A. Mokeem, BDS, MSc Department of Periodontics and Community Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
Aasem M AlhenakiAasem M Alhenaki, BDS, MSc Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
Fahim VohraFahim Vohra, MRD, PhD Department of Prosthetic Dental Science, College of Dentistry and Research Chair for Biological Research in Dental Health, College of Dentistry, Riyadh 11545, Saudi Arabia.
Tariq AbduljabbarTariq Abduljabbar, BDS, DMSc Department of Prosthetic Dental Science, College of Dentistry and Research Chair for Biological Research in Dental Health, College of Dentistry, Riyadh 11545, Saudi Arabia.
King Saud University · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveA comparison of the initial stability of narrow- and standard-diameter implants (SDIs) placed in Type-I and Type-IV bone-blocks is not yet reported. The aim was to evaluate in-vitro the influence of implant diameter on the initial stability of narrow- and standard-diameter implants (SDIs) placed in simulated Type-I and Type-IV bone-blocks.

methodsThe present experimental in-vitro study was performed between July and September 2020 at the Specialist Dental Practice, Riyadh, Saudi Arabia. Narrow- and standard-diameter implants were placed 3-mm apart in simulated soft (Type-IV) and dense (Type-I) bone blocks by a trained and calibrated investigator. In groups A (Type-IV bone blocks) and B (Type-I bone blocks), implants were inserted using an insertion-torque and drilling-speed of 15-30 Ncm and 1000-1500 rpm, respectively with the implant collar at the crest of simulated bone blocks. In all samples, initial-stability was recorded using resonance frequency analysis (RFA). Sample-size estimation was done and group-comparisons were carried out. A P-value of 0.01 or less reflected statistical significance.

resultsIn Groups-A and -B, 44 (22 NDIs and 22 SDIs) and 44 (22 NDIs and 22 SDIs) were placed. In group-A, the mean RFA values for NDIs and SDIs were 68.5 ± 3.5 and 69.1 ± 2.4, respectively. In Group-B, the mean RFA values for NDIs and SDIs were 78.06 ± 9.6 and 75.3 ± 5.2. RFA values among NDIs and SDIs in groups A and B were similar.

conclusionThe NDIs and SDIs show comparable initial-stability when positioned in simulated Type-I and Type-IV bone blocks.

Indexed as

Dental implantinitial stabilityIn-VitroNarrow diameterSimulated boneStandard diameter

Identifiers

PMID34104170
PMCPMC8155436
OpenAlexW3129633363

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.