Evidence map›Paper›PMID 34103854›Full record

ArticleAnnals of pediatric cardiology

Use of cribriform amplatzer septal occluder in the pediatric population: Feasibility, safety, and technical considerations.

Priya Pradhan, Sneha Jain, Supratim Sen, Bharat Dalvi

Open access · diamondAbstract read
In one paragraph

Article in Annals of pediatric cardiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Priya PradhanDepartment of Pediatric Cardiology, NHSRCC Hospital, Mumbai, Maharashtra, India.
Sneha JainDepartment of Pediatric Cardiology, NHSRCC Hospital, Mumbai, Maharashtra, India.
Supratim SenDepartment of Pediatric Cardiology, NHSRCC Hospital, Mumbai, Maharashtra, India.
Bharat DalviDepartment of Pediatric Cardiology, NHSRCC Hospital, Mumbai, Maharashtra, India.
National Health Systems Resource Centre · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFenestrated atrial septal defects (F-ASDs) in the pediatric population pose a challenge for transcatheter device closure since multiple devices are not preferred in small hearts. Oversizing the Amplatzer Septal Occluder (ASO) to cover the surrounding fenestrations usually distorts the central waist as well as the disc profile and often defeats the purpose. This is a retrospective observational study with an aim to assess the feasibility and safety of cribriform ASO in closing F-ASDs in small children.

methodsSixteen children with F-ASD who underwent device closure with cribriform ASO were included in the study. The fenestrated septal length (FSL) and the total septal length (TSL) were measured on transesophageal echocardiogram. A device size which was 1.5-2 times the FSL but smaller than the TSL was selected. The defect was closed with a device passed through a relatively centrally placed smaller fenestration.

resultsThe median age of the cohort was 5 years (2.5-10.5). Majority (14/16) required 25 or 30 mm cribriform ASO. Aneurysmal interatrial septum was seen in most of our patients (11/15). All the patients had successful device implantation. Complete closure of the defect was seen in 11 patients while 5 patients had insignificant residual shunt at a median follow-up of 40 months (1-60 months). There were no other complications.

conclusionsCribriform ASO can be used safely and effectively in closing F-ASDs in children. Deployment of the device through a small central hole allows covering maximum fenestrations and gives more stability to the device. Residual shunts, although not infrequent, are insignificant.

Indexed as

Cribriform devicemultifenestrated atrial septal defectnonself-centering atrial septal defect deviceseptal aneurysm

Identifiers

PMID34103854
PMCPMC8174635
OpenAlexW3155265758

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.