ArticleActa orthopaedica2021
The STRYDE limb lengthening nail is susceptible to mechanically assisted crevice corrosion: an analysis of 23 retrieved implants.
Article in Acta orthopaedica, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 25 citations in OpenAlex.
- Technical considerations and early results of magnetic compressive intramedullary nailing for tibial and femoral shaft non-unions: a case series.Annals of joint · 2026Article
- Disintegration of the Second-Generation Precice Bone Transport Nail During Removal Is Still an Issue: A Case Report.Case reports in orthopedics · 2026Article
- Plate-assisted bone-segment transport in the femur with 2 internal lengthening nails: a technical note and a case report.Acta orthopaedica · 2023Article
- Antegrade Intramedullary Femoral Lengthening and Distal Temporary Hemiepiphysiodesis for Combined Correction of Leg Length Discrepancy and Coronal Angular Deformity in Skeletally Immature Patients.Journal of clinical medicine · 2023Article
- Letter to the editor on "STRYDE versus PRECICE magnetic internal lengthening nail for femur lengthening".Archives of orthopaedic and trauma surgery · 2022Article
- Correction of post-traumatic lower-limb discrepancy with Precice intramedullary lengthening nails: a review of 34 adults with an average follow-up of 2 years.Acta orthopaedica · 2022Article
- Does Focal Osteolysis in a PRECICE Stryde Intramedullary Lengthening Nail Resolve after Explantation?Children (Basel, Switzerland) · 2022Article
- Technical considerations and early results of magnetic compressive intramedullary nailing for humeral shaft delayed unions and nonunions.JSES international · 2022Article
- Focal osteolysis and corrosion at the junction of Precice Stryde intramedullary lengthening device : preliminary clinical, radiological, and metallurgic analysis of 57 lengthened segments.Bone & joint research · 2021Article
- Bone Lengthening with a Motorized Intramedullary Nail in 34 Patients with Posttraumatic Limb Length Discrepancies.Journal of clinical medicine · 2021Article
- Limb reconstruction in a resource-limited environment.SICOT-J · 2021Article
- Fitbone vs Precice: Is There a Difference in Regenerate Healing?Strategies in trauma and limb reconstructionArticle
- Precice Stryde® Magnetic Internal Lengthening Nail does not Impair Bone Healing Despite Radiographic and Clinical Symptoms.Strategies in trauma and limb reconstructionArticle
- Mechanism Failures in Externally Controlled Motorized Intramedullary Lengthening Nails: A Systematic Review.JB & JS open accessReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and purpose - We noted several adverse events in patients in whom the first version of the STRYDE limb-lengthening nail (NuVasive Specialized Orthopaedics, San Diego, CA) had been implanted. Pain, osteolysis, periosteal reactions, and cortical hypertrophy at the nail junction were noted. Here, we present the analysis of 23 retrieved STRYDE implants.Materials and methods - We undertook visual inspection of the retrieved nails and screws, mechanical evaluation of the junction, micro-CT analyses, microscopic inspection of the bushing, screws, screw holes, and separated parts of the implants. Positive material identification (PMI) and energy-dispersive X-ray spectroscopy (EDS) were used to analyze the chemical composition. The hardness of the material was also investigated.Results - 20/23 retrieved nails had visible signs of corrosion, i.e., discoloration at the telescopic junction. Micro-CT verified corrosion attacks in 12/12 scanned bushings. Corrosion, predominantly mechanically assisted crevice corrosion, was observed at the locking screws and screw holes in 20/23 nails. Biological material inside the nail was observed in addition to oozing from the junction of 2 nails during hardware removal, which was experimentally reproducible. Notably, the mechanical construction of the bushing changed from PRECICE P2 to STRYDE nails.Interpretation - STRYDE nails are not hermetically sealed, and liquid can pass the bushing. Biodur 108 itself is corrosion resistant; however, mechanically assisted crevice corrosion of the bushing, locking screws, and screw holes may be aggravated due to manufacturing aiming for increased strength and hardness of the alloy.Observing several adverse events, we recently published a nationwide cross-sectional analysis of all 30 STRYDE limb- lengthening nails (NuVasive, Specialized Orthopedics, San Diego, CA) that were implanted in Denmark (Rölfing et al. 2021a). 27/30 STRYDE nails have now been removed and we present data from metallurgical analysis of 23 of the retrieved implants.