ArticleEJNMMI research2021
Automated and robust organ segmentation for 3D-based internal dose calculation.
Article in EJNMMI research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 18 citations in OpenAlex.
- Personalised Dosimetry in Nuclear Medicine: Bridging Physics, Biology and AI for Next Generation Radiopharmaceutical Therapy.Nuclear medicine and molecular imaging · 2026Review
- Evaluation of segmentation accuracy and the improvement of time effectiveness using deep learning-based segmentation inEJNMMI physics · 2026Article
- Inter-institutional variability in kidney dosimetry duringRadiological physics and technology · 2026Article
- Review
- Towards practical radiopharmaceutical treatment planning: a review of dosimetry simplification techniques.Theranostics · 2026Review
- Artificial intelligence across oncologic theranostics: evidence for patient stratification, dosimetry, and adaptive radiopharmaceutical therapy.Frontiers in nuclear medicine · 2026Review
- A paired multi-scale attention network for liver tumor segmentation in 99mTc-MAA SPECT/CT imaging.Scientific reports · 2025Article
- Radiomics and Artificial Intelligence in Radiotheranostics: A Review of Applications for Radioligands Targeting Somatostatin Receptors and Prostate-Specific Membrane Antigens.Diagnostics (Basel, Switzerland) · 2024Review
- Theranostics and artificial intelligence: new frontiers in personalized medicine.Theranostics · 2024Review
- Manual Versus Artificial Intelligence-Based Segmentations as a Pre-processing Step in Whole-body PET Dosimetry Calculations.Molecular imaging and biology · 2023Article
- Kidney Tumor Semantic Segmentation Using Deep Learning: A Survey of State-of-the-Art.Journal of imaging · 2022Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
purposeIn this work, we address image segmentation in the scope of dosimetry using deep learning and make three main contributions: (a) to extend and optimize the architecture of an existing convolutional neural network (CNN) in order to obtain a fast, robust and accurate computed tomography (CT)-based organ segmentation method for kidneys and livers; (b) to train the CNN with an inhomogeneous set of CT scans and validate the CNN for daily dosimetry; and (c) to evaluate dosimetry results obtained using automated organ segmentation in comparison with manual segmentation done by two independent experts.
methodsWe adapted a performant deep learning approach using CT-images to delineate organ boundaries with sufficiently high accuracy and adequate processing time. The segmented organs were consequently used as binary masks for further convolution with a point spread function to retrieve the activity values from quantitatively reconstructed SPECT images for "volumetric"/3D dosimetry. The resulting activities were used to perform dosimetry calculations with the kidneys as source organs.
resultsThe computational expense of the algorithm was sufficient for clinical daily routine, required minimum pre-processing and performed with acceptable accuracy a Dice coefficient of [Formula: see text] for liver segmentation and of [Formula: see text] for kidney segmentation, respectively. In addition, kidney self-absorbed doses calculated using automated segmentation differed by [Formula: see text] from dosimetry performed by two medical physicists in 8 patients.
conclusionThe proposed approach may accelerate volumetric dosimetry of kidneys in molecular radiotherapy with 177Lu-labelled radiopharmaceuticals such as 177Lu-DOTATOC. However, even though a fully automated segmentation methodology based on CT images accelerates organ segmentation and performs with high accuracy, it does not remove the need for supervision and corrections by experts, mostly due to misalignments in the co-registration between SPECT and CT images. Trial registration EudraCT, 2016-001897-13. Registered 26.04.2016, www.clinicaltrialsregister.eu/ctr-search/search?query=2016-001897-13 .
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.