Evidence map›Paper›PMID 34099942›Full record

ArticleNature protocols2021

Graphene- and metal-induced energy transfer for single-molecule imaging and live-cell nanoscopy with (sub)-nanometer axial resolution.

Arindam Ghosh, Alexey I Chizhik, Narain Karedla, Jörg Enderlein

Abstract read
PubMed Publisher
In one paragraph

Article in Nature protocols, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
10.2field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 46 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Arindam GhoshThird Institute of Physics-Biophysics, Georg August University, Göttingen, Germany.
Alexey I ChizhikThird Institute of Physics-Biophysics, Georg August University, Göttingen, Germany.
Narain KaredlaRosalind Franklin Institute, Didcot, UK.ORCID http://orcid.org/0000-0002-7891-3825
Jörg EnderleinThird Institute of Physics-Biophysics, Georg August University, Göttingen, Germany. jenderl@gwdg.de.ORCID http://orcid.org/0000-0001-5091-7157
University of Göttingen · DEUniversity of Oxford · GB

Funding

Deutsche Forschungsgemeinschaft (German Research Foundation) EXC 2067/1- 390729940Deutsche Forschungsgemeinschaft (German Research Foundation) SFB860, A06
6 · The paper itself

Abstract

Super-resolution fluorescence imaging that surpasses the classical optical resolution limit is widely utilized for resolving the spatial organization of biological structures at molecular length scales. In one example, single-molecule localization microscopy, the lateral positions of single molecules can be determined more precisely than the diffraction limit if the camera collects individual photons separately. Using several schemes that introduce engineered optical aberrations in the imaging optics, super-resolution along the optical axis (perpendicular to the sample plane) has been achieved, and single-molecule localization microscopy has been successfully applied for the study of 3D biological structures. Nonetheless, the achievable axial localization accuracy is typically three to five times worse than the lateral localization accuracy. Only a few exceptional methods based on interferometry exist that reach nanometer 3D super-resolution, but they involve enormous technical complexity and restricted sample preparations that inhibit their widespread application. We developed metal-induced energy transfer imaging for localizing fluorophores along the axial direction with nanometer accuracy, using only a conventional fluorescence lifetime imaging microscope. In metal-induced energy transfer, experimentally measured fluorescence lifetime values increase linearly with axial distance in the range of 0-100 nm, making it possible to calculate their axial position using a theoretical model. If graphene is used instead of the metal (graphene-induced energy transfer), the same range of lifetime values occurs over a shorter axial distance (~25 nm), meaning that it is possible to get very accurate axial information at the scale of a membrane bilayer or a molecular complex in a membrane. Here, we provide a step-by-step protocol for metal- and graphene-induced energy transfer imaging in single molecules, supported lipid bilayer and live-cell membranes. Depending on the sample preparation time, the complete duration of the protocol is 1-3 d.

Indexed as

Energy TransferAnimalsCell Line, TumorCell SurvivalData AnalysisDogsFluorescent DyesGraphiteHumansImaging, Three-DimensionalMadin Darby Canine Kidney CellsMetalsMicroscopy, FluorescenceNanotechnologySingle Molecule ImagingUser-Computer InterfaceFluorescent DyesGraphiteMetals

Identifiers

PMID34099942
OpenAlexW3172012183

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.