Evidence map›Paper›PMID 34098896›Full record

ArticleBMC medical imaging2021

Assessment of breast arteries and lymph nodes by 3D MR angiography enhancement imaging: feasibility and pilot clinical results.

Yang Liu, Jiaxin Hou, Zhijun Zhu, Bingguang Liu, Manrui Cao, Wenjian Qin

Abstract read
In one paragraph

Article in BMC medical imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yang LiuAffiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, People's Republic of China.
Jiaxin HouShenzhen Institute of Advanced Technology, Chinese Academy of Science, 1068 Xueyuan Avenue, Shenzhen, 518055, People's Republic of China.
Zhijun ZhuAffiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, People's Republic of China.
Bingguang LiuAffiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, People's Republic of China.
Manrui CaoAffiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, People's Republic of China. caomanrui@163.com.
Wenjian QinShenzhen Institute of Advanced Technology, Chinese Academy of Science, 1068 Xueyuan Avenue, Shenzhen, 518055, People's Republic of China. wj.qin@siat.ac.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundConventional dynamic contrast enhanced (DCE) magnetic resonance (MR) hardly achieves a good imaging performance of arteries and lymph nodes in the breast area. Therefore, a new imaging method is needed for the assessment of breast arteries and lymph nodes.

methodsWe performed prospective research. The research included 52 patients aged from 25 to 64 between June 2019 and April 2020. The isotropic e-THRIVE sequence scanned in the coronal direction after DCE-THRIVE. Reconstructed images obtained by DCE-THRIVE and the coronal e-THRIVE were compared mainly in terms of the completeness of the lateral thoracic artery, thoracodorsal artery, and lymph nodes. We proposed a criterion for evaluating image quality. According to the criterion, images were assigned a score from 1 to 5 according to the grade from low to high. Two board-certified doctors evaluated images individually, and their average score was taken as the final result. The chi-square test was used to assess the difference.

resultsThe coronal e-THRIVE score is 4.60, which is higher than the DCE-THRIVE score of 3.48, there are significant differences between the images obtained by two sequences (P = 1.2712e-8). According to the score of images, 44 patients (84.61%) had high-quality images on the bilateral breast. Only 3 patients' (5.77%) images were not ideal on both sides. The improved method is effective for most patients to get better images.

conclusionsThe proposed coronal e-THRIVE scan can get higher quality reconstruction images than the conventional method to visualize the course of arteries and the distribution of lymph nodes in most patients, which will be helpful for the clinical follow-up treatment.

Indexed as

AdultBreastBreast NeoplasmsChi-Square DistributionFeasibility StudiesFemaleHumansImaging, Three-DimensionalLymph NodesMagnetic Resonance AngiographyMiddle AgedPilot ProjectsProspective StudiesThoracic ArteriesBreast diseaseLateral thoracic arteryLymph nodesMagnetic resonance angiographyThoracodorsal artery

Identifiers

PMID34098896
PMCPMC8185933

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.