Evidence map›Paper›PMID 34096199›Full record

ArticleJournal of medical radiation sciences2021

Technical evaluation of a clinical, bi-planar, digital and upright X-ray imaging unit.

Charlotte Kelly, Ioannis Delakis

Abstract read
In one paragraph

Article in Journal of medical radiation sciences, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Charlotte KellyRadiology Department, Sidra Medical and Research Center, Doha, Qatar.
Ioannis DelakisRadiology Department, Sidra Medical and Research Center, Doha, Qatar.ORCID https://orcid.org/0000-0003-1497-2671

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We describe the technical evaluation of the commercially available, clinical, bi-planar, low dose, digital X-ray system (EOS System, EOS imaging, France). The unit is used for upright, weight-bearing musculoskeletal pathologies, in particular, in the spine and lower limbs. The evaluation incorporated tests on the X-ray generator performance, radiation/imaging field alignment, dose area product accuracy and image quality. The assessment methodology was based on objective parameters and required equipment readily available for technical evaluation of other radiological equipment. Results demonstrated that the system performs well within acceptable performance criteria with regard to X-ray generator performance, radiation/imaging field alignment and dose area product accuracy. In addition, results from the image-quality assessment were aligned with previously published work. The work presented in this article can be used for the technical evaluation of the EOS System at other clinical sites.

Indexed as

Lower ExtremityRadiographic Image EnhancementPhantoms, ImagingRadiation DosageRadiographyX-Raysdata collectionimagingphantomsquality controlradiation protectionradiologictechnology

Identifiers

PMID34096199
PMCPMC8655884

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.