Evidence map›Paper›PMID 34095981›Full record

Trial reportProgress in orthodontics2021

Factors influencing the removal torque of palatal implant used for orthodontic anchorage.

Marc Andreas Schätzle, Monika Hersberger-Zurfluh, Raphael Patcas

Open access · diamondAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Progress in orthodontics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 61% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Marc Andreas SchätzleClinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, CH-8032, Zurich, Switzerland. marc.schaetzle@zzm.uzh.ch.ORCID http://orcid.org/0000-0003-2019-5223
Monika Hersberger-ZurfluhClinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, CH-8032, Zurich, Switzerland.
Raphael PatcasClinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, CH-8032, Zurich, Switzerland.
University of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA non-invasive method has recently been introduced to remove osseo-integrated palatal implants by using the implantation ratchet which is designed to screw in or unscrew the implants. Although a proof of concept has been published, the torque involved to successfully explant have not been investigated so far. The aim of this study was to assess the removal torque required to explant osseo-integrated and orthodontically utilized palatal implants, and to identify potentially influencing variables. MATERIALS AND

methodThirty-one consecutive patients (15 females, 16 males; mean age 24.1 ±7.4 years) with fully osseo-integrated and previously orthodontically loaded palatal implants (Orthosystem®: diameter 4.1mm/length 4.2mm/sandblasted with large grits (SLA) surface) were randomly assigned to either clockwise or counter-clockwise non-invasive explantation. The respective explantation tool with an electric torque control was placed on the abutment connection of the implant and secured by an occlusal screw. The primary outcome studied was maximal removal torque (MRT) needed to detach the implant from its socket which was recorded individually together with other potentially influencing secondary outcomes (gender, age, orthodontic loading time, use of local anaesthetics). Student's t-test was used to contrast MRT difference for the gender, type of suprastructure, use of local anaesthetics, and rotational direction. Spearman correlations was used to investigate associations between MRT and patient's age or duration loading time.

resultsAverage MRT (148.6 ± 63.2N/cm) using ratchet as a non-invasive removal method of palatal implant was considered safe. The triangular head fractured of palatal implant at a torque level of 300.1 Ncm. Significantly higher explantation were recorded for male patients compared to female patients (182.0 ± 63.0 Ncm vs 112.8 ± 40.8 Ncm; P=0.001). On the other side, the mean removal torque for palatal removal in clockwise direction was non-significantly different (158.3 ± 58.6 Ncm) compared to counter-clockwise direction (139.4 ± 67.9 Ncm). Neither patient's age (p=0.324) nor loading time (p=0.214) were significantly correlated with removal torque values.

conclusionsPertinent literature on this subject is practically non-existent, as orthodontics is presumably the only discipline where implant removal represents a treatment success. Mean MRT for successful palatal implant removal was 148.6±63.2Ncm, but a large spectrum was observed (minimum 31.5Ncm, maximum 272.8Ncm). This obvious heterogeneity underlines the importance to investigate possible influencing factors. The safe and simple non-invasive method for palatal implant removal necessitates moderate, but not high torque MRTs, independently of the torque direction. The necessary MRT seems clearly influenced by gender, but less so by patient's age or loading time.

Indexed as

Dental ImplantsAdolescentAdultBone ScrewsDevice RemovalFemaleHumansMalePalateTorqueYoung AdultDental ImplantsComplicationsHumanPalatal implantsRemovalSkeletal anchorageSurgicalTorque

Identifiers

PMID34095981
PMCPMC8180535
OpenAlexW3167299750

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.