Evidence map›Paper›PMID 34095816›Full record

ArticleFrontiers in artificial intelligence2021

CNN-Based LCD Transcription of Blood Pressure From a Mobile Phone Camera.

Samruddhi S Kulkarni, Nasim Katebi, Camilo E Valderrama, Peter Rohloff, Gari D Clifford

Open access · goldAbstract read
In one paragraph

Article in Frontiers in artificial intelligence, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.2field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Samruddhi S KulkarniSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, United States.
Nasim KatebiDepartment of Biomedical Informatics, Emory University, Atlanta, GA, United States.
Camilo E ValderramaDepartment of Biomedical Informatics, Emory University, Atlanta, GA, United States.
Peter RohloffWuqu' Kawoq | Maya Health Alliance, Chimaltenango, Guatemala.
Gari D CliffordDepartment of Biomedical Informatics, Emory University, Atlanta, GA, United States.
Emory University · USBrigham and Women's Hospital · USGeorgia Institute of Technology · US

Funding

Implementing a Maternal health and PRegnancy Outcomes Vision for Everyone (IMPROVE)UL1TR002378 · NCATS · EMORY UNIVERSITY · PI Andres J Garcia, Elizabeth O. Ofili · 2017 to 2026
$92.1M
Mobile Health Intervention to Improve Perinatal Continuum of Care in GuatemalaR21HD084114 · NICHD · EMORY UNIVERSITY · PI CLIFFORD, GARI DAVID · 2015 to 2016
$374k
NCATS NIH HHS UL1 TR002378NICHD NIH HHS R21 HD084114
6 · The paper itself

Abstract

Routine blood pressure (BP) measurement in pregnancy is commonly performed using automated oscillometric devices. Since no wireless oscillometric BP device has been validated in preeclamptic populations, a simple approach for capturing readings from such devices is needed, especially in low-resource settings where transmission of BP data from the field to central locations is an important mechanism for triage. To this end, a total of 8192 BP readings were captured from the Liquid Crystal Display (LCD) screen of a standard Omron M7 self-inflating BP cuff using a cellphone camera. A cohort of 49 lay midwives captured these data from 1697 pregnant women carrying singletons between 6 weeks and 40 weeks gestational age in rural Guatemala during routine screening. Images exhibited a wide variability in their appearance due to variations in orientation and parallax; environmental factors such as lighting, shadows; and image acquisition factors such as motion blur and problems with focus. Images were independently labeled for readability and quality by three annotators (BP range: 34-203 mm Hg) and disagreements were resolved. Methods to preprocess and automatically segment the LCD images into diastolic BP, systolic BP and heart rate using a contour-based technique were developed. A deep convolutional neural network was then trained to convert the LCD images into numerical values using a multi-digit recognition approach. On readable low- and high-quality images, this proposed approach achieved a 91% classification accuracy and mean absolute error of 3.19 mm Hg for systolic BP and 91% accuracy and mean absolute error of 0.94 mm Hg for diastolic BP. These error values are within the FDA guidelines for BP monitoring when poor quality images are excluded. The performance of the proposed approach was shown to be greatly superior to state-of-the-art open-source tools (Tesseract and the Google Vision API). The algorithm was developed such that it could be deployed on a phone and work without connectivity to a network.

Indexed as

blood pressureconvolutional neural networkdigital transcriptionhypertensionoptical character recognitionpreeclampsia

Identifiers

PMID34095816
PMCPMC8177819
OpenAlexW3165458365

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.