Evidence map›Paper›PMID 34095415›Full record

ArticlePractical laboratory medicine2021

Survey of renin and aldosterone testing practices by Ontario laboratories - Providing insight into best practices.

Angela C Rutledge, Anna Johnston, Dana Bailey, Ronald A Booth, Pamela Edmond, Victor Leung, Kika Veljkovic

Abstract read
In one paragraph

Article in Practical laboratory medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Do not take a chance! We do not tell fortunes.Hypertension research : official journal of the Japanese Society of Hypertension · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Angela C RutledgeEndocrinology and Immunology Scientific Committee, Institute for Quality Management in Healthcare, Toronto, Ontario, Canada.
Anna JohnstonInstitute for Quality Management in Healthcare, Toronto, Ontario, Canada.
Dana BaileyEndocrinology and Immunology Scientific Committee, Institute for Quality Management in Healthcare, Toronto, Ontario, Canada.
Ronald A BoothEndocrinology and Immunology Scientific Committee, Institute for Quality Management in Healthcare, Toronto, Ontario, Canada.
Pamela EdmondEndocrinology and Immunology Scientific Committee, Institute for Quality Management in Healthcare, Toronto, Ontario, Canada.
Victor LeungEndocrinology and Immunology Scientific Committee, Institute for Quality Management in Healthcare, Toronto, Ontario, Canada.
Kika VeljkovicEndocrinology and Immunology Scientific Committee, Institute for Quality Management in Healthcare, Toronto, Ontario, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTesting for renin and aldosterone in clinical laboratories is complicated by pre-analytical considerations such as the posture for blood collection and susceptibility to cryoactivation of renin. From an analytical perspective, there are both renin activity and renin mass or concentration assays available. There can also be variability in result reporting practices and the aldosterone-renin ratio (ARR) cut-off applied to screen for primary aldosteronism (PA). The Institute for Quality Management in Healthcare (IQMH) Centre for Proficiency Testing surveyed laboratories on their handling of renin and aldosterone testing to better understand current practices. DESIGN AND

methodsAn online survey was prepared and sent to 134 Canadian laboratories enrolled in endocrinology proficiency testing with IQMH.

resultsOne hundred twenty Ontario laboratories submitted responses. While only six (5%) laboratories perform testing for both renin and aldosterone, 108 (90%) collect and process specimens to be tested by reference laboratories. The survey revealed considerable variation in practices including the recommended state of patients prior to sample collection (for example, regarding medications or salt intake), the patient posture specifications for sample collection, the precautions taken against cryoactivation of renin, the choice of renin activity or mass assay, and the ARR cut-off used. The available literature on these factors was then reviewed.

conclusionsAlthough there is no standardized procedure for specimen collection, analysis, or result reporting for renin or aldosterone testing, we have attempted to summarize the available literature to develop evidence-based recommendations. Where laboratory practice differs from peers and/or recommended protocols, laboratories should review their practices.

Indexed as

AldosteroneAldosterone-renin ratioARR, aldosterone-renin ratioCryoactivationIQMH, Institute for Quality Management in HealthcarePA, primary aldosteronismPrimary aldosteronismRenin

Identifiers

PMID34095415
PMCPMC8145751

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.