Evidence map›Paper›PMID 34094456›Full record

ArticleChemical science2020

Selectively detecting attomolar concentrations of proteins using gold lined nanopores in a nanopore blockade sensor.

Yanfang Wu, Yin Yao, Soshan Cheong, Richard D Tilley, J Justin Gooding

Abstract read
In one paragraph

Article in Chemical science, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yanfang WuSchool of Chemistry, Australian Centre for NanoMedicine, Australian Research Council Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales Sydney New South Wales 2052 Australia yanfang.wu@unsw.edu.au justin.gooding@unsw.edu.au.ORCID https://orcid.org/0000-0003-4201-2061
Yin YaoElectron Microscope Unit, Mark Wainwright Analytical Centre, University of New South Wales Sydney New South Wales 2052 Australia.
Soshan CheongElectron Microscope Unit, Mark Wainwright Analytical Centre, University of New South Wales Sydney New South Wales 2052 Australia.ORCID https://orcid.org/0000-0001-6133-0829
Richard D TilleySchool of Chemistry, Australian Centre for NanoMedicine, Australian Research Council Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales Sydney New South Wales 2052 Australia yanfang.wu@unsw.edu.au justin.gooding@unsw.edu.au.ORCID https://orcid.org/0000-0003-2097-063X
J Justin GoodingSchool of Chemistry, Australian Centre for NanoMedicine, Australian Research Council Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales Sydney New South Wales 2052 Australia yanfang.wu@unsw.edu.au justin.gooding@unsw.edu.au.ORCID https://orcid.org/0000-0002-5398-0597

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Disease diagnosis at earlier stages requires the development of ultrasensitive biosensors for detecting low-abundance biomarkers in complex biological fluids within a reasonable time frame. Here, we demonstrate the development of an ultrasensitive nanopore blockade biosensor that can rapidly diagnose a model protein biomarker, prostate-specific antigen (PSA) with high selectivity. The solid-state nanopores have gold located only along the length of the nanopore whilst the rest of the membrane is silicon nitride. The orthogonal use of materials allows nanopore arrays with a different surface chemistry inside the nanopore relative to the rest of the membrane to be fabricated. The importance of this differential surface chemistry is it can improve the detection limit of nanopore blockade sensors in quantitative analysis. Based on such functionalized nanopore devices, nanopore blockade sensors lower the limit of detection by an order of magnitude and enable ultrasensitive detection of PSA as low as 80 aM. The findings from this study open new opportunities for nanopore sensors in further developments including optical detection and ultralow detection limit biosensing at complex biological fluids.

Identifiers

PMID34094456
PMCPMC8163308

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.