Evidence map›Paper›PMID 34094007›Full record

ArticleClinics in orthopedic surgery2021

Treatment of 10-mm-Deep or Greater Uncontained Tibial Bone Defects in Primary Total Knee Reconstruction without Metal Augmentation: Autologous Oblique Structural Peg Bone and Cancellous Chip Bone Grafting.

Je-Gyun Chon, Jong-Won Kang, Cheol-U Kim, Uitak Jeong, Jongjin Go

Open access · diamondAbstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Autogenous structural bone graft reconstruction of ≥ 10-mm-deep uncontained medial proximal tibial defects in primary total knee arthroplasty.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Je-Gyun ChonDepartment of Orthopaedic Surgery, Daejeon Sun Hospital, Daejeon, Korea.ORCID https://orcid.org/0000-0002-1526-8259
Jong-Won KangDepartment of Orthopaedic Surgery, Daejeon Sun Hospital, Daejeon, Korea.ORCID https://orcid.org/0000-0002-5998-1507
Cheol-U KimDepartment of Orthopaedic Surgery, Daejeon Sun Hospital, Daejeon, Korea.ORCID https://orcid.org/0000-0002-0472-6007
Uitak JeongDepartment of Orthopaedic Surgery, Daejeon Sun Hospital, Daejeon, Korea.ORCID https://orcid.org/0000-0003-0156-5102
Jongjin GoDepartment of Orthopaedic Surgery, Daejeon Sun Hospital, Daejeon, Korea.ORCID https://orcid.org/0000-0002-4743-4434
Daejeon Sun Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroudIn this study, we report satisfactory clinical and radiological outcomes after autologous oblique structural peg bone and cancellous chip bone grafting without metal augmentation, including the use of a metal wedge, block, or additional stem, for patients with ≥ 10-mm-deep uncontained medial proximal tibial bone defects in primary total knee replacement.

methodsThe study group included 40 patients with primary total knee replacement with ≥ 10-mm-deep uncontained tibial bone defects who underwent autologous oblique structural peg bone and cancellous chip bone grafting and were followed-up for at least 1 year. Tibial cutting was performed up to a depth of 10 mm from the articular surface of the lateral tibial condyle, after which the height and area of the remaining bone defect in the medial condyle were measured. The bone defect was treated by making a peg bone and chip bone using excised segments of the tibia and femur. In all cases, the standard tibial stem and full cemented fixation techniques were used without metal augmentation. Preoperative and final follow-up radiologic changes and clinical measures were compared, and prosthesis loosening and bone union were checked radiologically at final follow-up.

resultsThe mean depth of the bone defects was 10.9 mm, and the mean percentage of the area occupied by bone defects in the axial plane was 18.4%. The mean mechanical femorotibial angle was corrected from 19.5° varus preoperatively to 0.2° varus postoperatively (

conclusionsEven in patients with uncontained tibial bone defects ≥ 10-mm deep in primary total knee replacement, if the defect occupies less than 30% of the cut surface, autologous oblique structural peg bone and cancellous chip bone grafting can be used to achieve satisfactory outcomes with a standard tibial stem and no metal augmentation.

Indexed as

Knee ProsthesisAgedAged, 80 and overArthroplasty, Replacement, KneeBone TransplantationCohort StudiesFemaleHumansMaleOsteoarthritis, KneeProspective StudiesTibiaTransplantation, AutologousAutologous bone graftRadiographyTibial bone defectTotal knee arthroplasty

Identifiers

PMID34094007
PMCPMC8173235
OpenAlexW3134433899

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.