Evidence map›Paper›PMID 34093969›Full record

ArticleIEEE International Ultrasonics Symposium : [proceedings]. IEEE International Ultrasonics Symposium2018

3-D Motion Correction for Volumetric Super-Resolution Ultrasound Imaging.

Sevan Harput, Kirsten Christensen-Jeffries, Jemma Brown, Jiaqi Zhu, Ge Zhang, Robert J Eckersley, Chris Dunsby, Meng-Xing Tang

Abstract read
In one paragraph

Article in IEEE International Ultrasonics Symposium : [proceedings]. IEEE International Ultrasonics Symposium, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. High-Volume Acquisition Rate Nonlinear Imaging Enables Robust 3-D Ultrasound Localization Microscopy.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025
    Article
  2. Advancements in Three-Dimensional Super-Resolution Ultrasound Imaging: A Narrative Review.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Review
  3. Review
  4. Ultrasound localization microscopy.Zeitschrift fur medizinische Physik · 2023
    Review
  5. Review
  6. Super-resolution Ultrasound Imaging.Ultrasound in medicine & biology · 2020
    Review
  7. 3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sevan HarputULIS Group, Department of Bioengineering, Imperial College London, London, SW7 2BP, UK.
Kirsten Christensen-JeffriesBiomedical Engineering Department, Division of Imaging Sciences, King's College London, SE1 7EH, London, UK.
Jemma BrownBiomedical Engineering Department, Division of Imaging Sciences, King's College London, SE1 7EH, London, UK.
Jiaqi ZhuULIS Group, Department of Bioengineering, Imperial College London, London, SW7 2BP, UK.
Ge ZhangULIS Group, Department of Bioengineering, Imperial College London, London, SW7 2BP, UK.
Robert J Eckersley *Biomedical Engineering Department, Division of Imaging Sciences, King's College London, SE1 7EH, London, UK.
Chris Dunsby *Department of Physics and the Centre for Pathology, Imperial College London, London, SW7 2AZ, UK.
Meng-Xing Tang *ULIS Group, Department of Bioengineering, Imperial College London, London, SW7 2BP, UK.

Funding

Wellcome Trust 203148
6 · The paper itself

Abstract

Motion during image acquisition can cause image degradation in all medical imaging modalities. This is particularly relevant in 2-D ultrasound imaging, since out-of-plane motion can only be compensated for movements smaller than elevational beamwidth of the transducer. Localization based super-resolution imaging creates even a more challenging motion correction task due to the requirement of a high number of acquisitions to form a single super-resolved frame. In this study, an extension of two-stage motion correction method is proposed for 3-D motion correction. Motion estimation was performed on high volumetric rate ultrasound acquisitions with a handheld probe. The capability of the proposed method was demonstrated with a 3-D microvascular flow simulation to compensate for handheld probe motion. Results showed that two-stage motion correction method reduced the average localization error from 136 to 18

Identifiers

PMID34093969
PMCPMC7610905

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.