ArticleAnesthesia, essays and researches
Supraglottic Airway Devices for Elective Pediatric Anesthesia: I-gel versus Air-Q, Which is the Best?
Article in Anesthesia, essays and researches. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06677567 (Comparison of the Efficacy of Self-Pressurizing Air-Q Intubation Laryngeal Airway and Proseal Laryngeal Mask in Elderly Patients), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison of the Efficacy of Self-Pressurizing Air-Q Intubation Laryngeal Airway and Proseal Laryngeal Mask in Elderly Patients
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThe objectives of the study were to compare the insertion facility, the effect on hemodynamic parameters, and effective ventilation using I-gel versus Air-Q supraglottic airway devices (SADs) for pediatric patients undergoing short-duration surgical procedures. PATIENTS AND
methodsOne hundred and fifty children aged 3-10 years were randomly divided into two equal groups: Group I received I-gel and Group Q received Air-Q SAD. All patients were anesthetized by sevoflurane inhalation using a face mask without neuromuscular blockade. Study outcomes included SAD insertion success rate (SR), insertion time, anatomic alignment of the SAD to the larynx as judged using fiberoptic bronchoscope (FOB) inserted through the SAD, and tidal volume leak, and incidence of postoperative complications.
resultsTotal and first attempt SRs were 97.3% and 85.3% for I-gel and 94.7% and 82.7% respectively, for Air-Q with nonsignificant differences. However, I-gel insertion time (12.3 ± 3.6 s.) was significantly (
conclusionBoth Air-Q and I-gel SAD provided advantages for pediatric anesthesia during short-duration surgical procedure with nonsignificant differences. However, I-gel SAD required a shorter insertion time and provided a high SR which is satisfactory for trainees and during an emergency. I-gel SAD allowed minimization of tidal volume leak and gastric inflation and is associated with infrequent complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.