ArticlePediatric research2022
Detecting acute bilirubin encephalopathy in neonates based on multimodal MRI with deep learning.
Article in Pediatric research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 17 citations in OpenAlex.
- KD-SqueezeNet: an efficient deep learning strategy for the multi-task diagnosis of neonatal lung diseases.Pediatric radiology · 2026Article
- Diagnosing acute bilirubin encephalopathy in neonates using MRI-based deep learning model.BMC pediatrics · 2025Article
- Association of T1-weighted hyperintensity with timing of peak bilirubin levels in neonates with hyperbilirubinemia.Neuroradiology · 2025Article
- Detecting acute bilirubin encephalopathy in neonates based on multimodal MRI images and non-image clinical data.BMC pediatrics · 2025Article
- Visualization of Unconjugated Bilirubin In Vivo with a Novel Approach Using Chemical Exchange Saturation Transfer Magnetic Resonance Imaging in a Rat Model.ACS chemical neuroscience · 2024Article
- Automatic deep learning method for analysis and prediction of neonatal hyperbilirubinemia in magnetic resonance imaging.Quantitative imaging in medicine and surgery · 2024Article
- The Severity of Direct Antiglobulin Test Negative ABO Hemolytic Disease of Newborn: A Retrospective Analysis at a Tertiary Children's Hospital.Indian journal of hematology & blood transfusion : an official journal of Indian Society of Hematology and Blood Transfusion · 2024Article
- Deep Learning Network with Spatial Attention Module for Detecting Acute Bilirubin Encephalopathy in Newborns Based on Multimodal MRI.Diagnostics (Basel, Switzerland) · 2023Article
- Development and evaluation clinical-radiomics analysis based on T1-weighted imaging for diagnosing neonatal acute bilirubin encephalopathy.Frontiers in neurology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDifferentiating acute bilirubin encephalopathy (ABE) from non-ABE in neonates with hyperbilirubinemia (HB) from routine magnetic resonance imaging (MRI) is extremely challenging since both conditions demonstrate similar T1 hyperintensities. To this end, we investigated whether the integration of multimodal MRI from routine clinical scans with deep-learning approaches could improve diagnostic performance.
methodsA total of 75 neonates with ABE and 75 neonates with HB (non-ABE) were included in the study. Each patient had three types of multimodal images taken, i.e., a T1-weighted image (T1WI), a T2-weighted image (T2WI), and an apparent diffusion coefficient (ADC) map. The three types of MRI contrasts and their combination were fed into two deep convolutional neural networks (CNNs), i.e., ResNet18 and DenseNet201. The performance of CNNs was compared with a traditional statistical method named logistic regression.
resultsWe demonstrated that diagnostic methods with the multimodal data were better than any of the single-modal data. Both CNN models outperformed the logistic regression method. The best performance was achieved by DenseNet201 with the combination of three modalities of T1WI, T2WI, and ADC, with an accuracy of 0.929 ± 0.042 and an area under the curve (AUC) of 0.991 ± 0.007.
conclusionsOur study demonstrated that CNN models with multimodal MRI significantly improve the accuracy of diagnosing ABE. IMPACT: We proposed an efficient strategy of detecting ABE in neonates based on multimodal MRI with deep learning, which achieved an accuracy of 0.929 ± 0.042 and an AUC of 0.991 ± 0.007. We demonstrated the advantage of integrating multimodal MRI in detecting ABE in neonates with HB, using deep-learning models. Our strategy of diagnosing ABE using deep-learning techniques with multimodal MRI from routine clinical scans is potentially applicable to clinical practice.
Indexed as
Identifiers
What OpenQuestion holds