Evidence map›Paper›PMID 34086567›Full record

ArticleIEEE transactions on medical imaging2021

Divergence-Free Constrained Phase Unwrapping and Denoising for 4D Flow MRI Using Weighted Least-Squares.

Jiacheng Zhang, Sean M Rothenberger, Melissa C Brindise, Michael B Scott, Haben Berhane, Justin J Baraboo, Michael Markl, Vitaliy L Rayz, Pavlos P Vlachos

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. 4D flow MRI velocity uncertainty quantification.Magnetic resonance in medicine · 2025
    Article
  3. Article
  4. 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jiacheng Zhang
Sean M Rothenberger
Melissa C Brindise
Michael B Scott
Haben Berhane
Justin J Baraboo
Michael Markl
Vitaliy L Rayz
Pavlos P Vlachos

Funding

Risk Assessment of Cerebral Aneurysm Growth with 4D flow MRIR01HL115267 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI ANSARI, SAMEER A, LAWTON, MICHAEL T · 2013 to 2023
$4.2M
Graduate Training Program for Magnetic Resonance ImagingT32EB025766 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI Michael Markl · 2019 to 2026
$1.6M
Multi-modality 4D Flow MRI data enhancement for quantification of cerebral aneurysms hemodynamicsR21NS106696 · NINDS · PURDUE UNIVERSITY · PI RAYZ, VITALIY L, SCHNELL, SUSANNE · 2018 to 2019
$419k
NHLBI NIH HHS R01 HL115267NIBIB NIH HHS T32 EB025766NINDS NIH HHS R21 NS106696
6 · The paper itself

Abstract

A novel divergence-free constrained phase unwrapping method was proposed and evaluated for 4D flow MRI. The unwrapped phase field was obtained by integrating the phase variations estimated from the wrapped phase data using weighted least-squares. The divergence-free constraint for incompressible blood flow was incorporated to regulate and denoise the resulting phase field. The proposed method was tested on synthetic phase data of left ventricular flow and in vitro 4D flow measurement of Poiseuille flow. The method was additionally applied to in vivo 4D flow measurements in the thoracic aorta from 30 human subjects. The performance of the proposed method was compared to the state-of-the-art 4D single-step Laplacian algorithm. The synthetic phase data were completely unwrapped by the proposed method for all the cases with velocity encoding (venc) as low as 20% of the maximum velocity and signal-to-noise ratio as low as 5. The in vitro Poiseuille flow data were completely unwrapped with a 60% increase in the velocity-to-noise ratio. For the in-vivo aortic datasets with venc ratio less than 0.4, the proposed method significantly improved the success rate by as much as 40% and reduced the velocity error levels by a factor of 10 compared to the state-of-the-art method. The divergence-free constrained method exhibits reliability and robustness on phase unwrapping and shows improved accuracy of velocity and hemodynamic quantities by unwrapping the low-venc 4D flow MRI data.

Indexed as

Imaging, Three-DimensionalPhase VariationAlgorithmsBlood Flow VelocityHumansMagnetic Resonance ImagingPhantoms, ImagingReproducibility of Results

Identifiers

PMID34086567
PMCPMC8714458

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.